Work input
W = F × (N h / 12) + Wstring
Heat absorbed
Q = Cwater-eq × ΔT
Mechanical equivalent
J = W / Q
The historical noise model bootstraps the 40 same-numbered friction-minus-radiation pairs in Joule’s Table I. Their measured standard deviation is 0.01006 °F. Each simulated pair receives a bounded 0.005 °F quantisation term. The original correction also used a measured room-exchange coefficient of 0.04654 °F per °F of air-to-apparatus temperature difference over a run.
The modern comparison is 778.17 ft·lbf per BtuIT. The historical pound-of-water-per-degree unit is close, but not identical, to the modern defined Btu; treat the percentage comparison as indicative. Rowland’s 1880 thermometer re-reduction moved Joule’s 1850 water result to 778.0.
Simplifications: the falling load is treated as a constant effective force; shaft and string corrections are bundled into the historical work correction; the water and copper/brass parts share one lumped temperature; the empirical residuals represent combined reading and short-term environmental scatter. The unmodelled-leak control deliberately adds a systematic error. The mechanism animation is time-compressed; the work and heat calculation uses full-run quantities.