The weight of warmth.
Let falling weights turn a brass paddle through water. Measure an almost invisible rise in temperature—and find out how much work makes a unit of heat.
with paired controls
The weights are suspended. Start a trial to turn their gravitational energy into heat.
A very small change.
Repeat. Compare. Refine.
Joule's notebook.
Joule's reported result for stirring water. Equivalent to 4.157 J/cal using SI conversions.
The bar is reconstructed from Joule's reported run-to-run scatter, not an error bar he published. It captures random spread only, not calibration or other systematic uncertainty.
Four ways to check the physics.
THE SCIENCE Equations, noise, limitations and provenance+
From falling weights to warm water
Two masses fall through a measured height. Their work is W = 2 m g h N η. In an insulated vessel, W = (m_water + m_equiv) c ΔT; m_equiv is the brass and copper vessel expressed as an equivalent mass of water.
For heat exchange with the room we integrate C dT/dt = P − k(T − T_room), with C = (m_water + m_equiv)c and P = W / τ. The exact constant-power solution is independently checked against fixed-step numerical integration.
What the thermometer actually tells you
A paired no-stir trial estimates background heat exchange. The simulation subtracts its measured rise, then divides by the response factor A = (1 − exp(−kτ/C)) / (kτ/C) to correct remaining leakage. With negligible leakage, A → 1.
Readings combine historically motivated 0.005 °F sensitivity with explicitly illustrative Gaussian reading noise, rounded thermometer ticks and slow correlated laboratory drift (Ornstein–Uhlenbeck process). These are model assumptions, not recovered probabilities from Joule's notebook.
Why your number may differ
Joule reported 772.692 ft·lbf per pound-degree Fahrenheit (1850). The modern textbook comparison is 4.184 J per thermochemical calorie, an exact conversion by convention, not a fixed universal heat capacity of water. The original paper supplied no formal confidence interval. We derive an approximate 95% mean interval using paired radiation-corrected rises from 40 water runs and height-normalized work. Systematic uncertainty remains unquantified.
Real water heat capacity changes with temperature. This simplified constant-heat-capacity model assumes well-mixed water, constant pulley efficiency and uniform work delivery. The animation is time-compressed and dimensional proportions are illustrative. Not affiliated with any museum or historical institution.