From falling weights to heat
The available gravitational work is modelled as W = (2m − mloss) g h N + Wstring. The pulley-loss correction is scaled from Joule’s measured 2,837-grain loss over twenty descents.
The water and calorimeter warm according to Q = C ΔT, with C = (mwater + mvessel,eq) cp. The equivalent water mass of the copper vessel, brass wheel and stopper is taken from Joule’s capacity table.
The inferred mechanical equivalent is J = W / (meq,lb ΔT°F), reported in foot-pound-force per Btu.
Why the readings wander
The random run-to-run term is Gaussian, with its standard deviation calculated from the forty raw friction temperature gains in Joule’s Table I (0.03595 °F). Each start and finish reading is then rounded to the selected thermometer increment. The default increment, 0.005 °F, is the readability Joule reported.
The room correction models Joule’s paired radiation-only trials: a mean 0.012975 °F drift is removed, together with an extra gradient term using his measured coefficient of 0.04654 °F per °F mismatch over a 35-minute experiment. The historical scatter combines several effects; it is not treated as pure thermometer noise.
What is simplified
The moving weights are animated at an accelerated visual rate; the numerical work uses the energy balance, not the animation speed. The model holds water specific heat constant at 4,184 J kg⁻¹ K⁻¹, treats the metal heat capacity as an equivalent mass of water, and represents the many small environmental effects with a measured scatter term. It does not reproduce every correction in Joule’s 24-page paper.
This is an educational reconstruction, not an official exhibit of the Royal Society, the Science Museum Group, or any historical institution.