Joule’s Paddle Wheel: Turning Work into Heat
Can falling weights warm a vessel of water? Rebuild Joule’s measurement, repeat the drops, and estimate the mechanical equivalent of heat.
Your repeat experiment
0 trialsApparatus settings
Joule baseline · adjustableJoule’s original record
Table I · water series · 1849Independent numerical checks
live validationThe science · equations, noise and limits
Work becomes heat
W = 2 m (h / 12) N (1 − f) + 0.8464 NHere m is each hanging weight in pound-force, h is the fall in inches, N is the number of drops and f is the measured pulley-and-cord loss fraction. The final term is Joule’s 0.8464 ft·lbf string-elasticity correction per drop, scaled linearly with changed mass and fall height as a first-order model.
ΔT = W / (J C) ; Ĵ = W / (C ΔTcorrected)C is the total water-equivalent thermal load. The historical value is 13.9243 lb water-equivalent, including the copper vessel, brass wheel and stopper—not just the liquid water.
What makes a reading noisy?
Each thermometer reading is rounded to its stated step, so the difference contains two independent uniform quantisation errors. An independent Gaussian residual represents unresolved run-to-run scatter; its default is calibrated to the sample SD of the 40 original friction temperature rises (0.03595 °F). Air exchange is modelled separately as ΔTleak = 0.04654 × (Tair − Tvessel) per 35-minute trial, using Joule’s blank-run coefficient. The checkbox applies or omits this correction.
What is historical, and what is reconstructed?
The apparatus, nominal weights, fall, repeat count, thermal capacity, thermometer readability, original readings and published equivalent are historical. The live repeat is a transparent stochastic reconstruction, not a claim to reproduce every mechanical detail or every correction in Joule’s laboratory. The Monte Carlo validation uses a fixed seed so its displayed result is repeatable.
Joule reported 772.692 ft·lbf per lb·°F after his vacuum correction. The modern comparison uses 4,185.5 J kg⁻¹ K⁻¹ for water at 15 °C, converted to about 777.93 ft·lbf per lb·°F. Water’s heat capacity varies with temperature and convention, so this is a stated reference, not a universal constant.
This educational reconstruction is independent and is not affiliated with the Royal Society or any museum. Values marked historical come from Joule’s 1850 paper; live values are simulated.
Historical apparatus and measurements: J. P. Joule, “On the Mechanical Equivalent of Heat,” Philosophical Transactions of the Royal Society, 140 (1850), 61–82. Modern reference is labelled separately from the historical result.