THE EXPERIMENT ARCHIVEPHYSICS / HEAT
INTERACTIVE FIELD STUDY № 014
THE ORIGINAL APPARATUS · 1849–1850 RECONSTRUCTION

Weighing the heat of motion.

Can a falling weight tell you how much energy is hidden in a degree of warmth?

JOULE'S PADDLE WHEELManchester, England · 1850 water series
APPARATUS / CROSS SECTION
FIG. 01 Copper calorimeter · brass stirrer · paired lead weights
↔ DRAG TO INSPECT
WATER TEMPERATURE MODEL
14.600 °C
ΔT +0.000 °F
DELIVERED WORK MODEL
0.00 kJ
0 of 20 falls
YOUR MEASUREMENT ESTIMATE
— J / cal
Start a trial to collect a reading
THERMAL ENERGY MODEL
0.00 kJ
Heat exchanged: 0.0 J
OBSERVATION / REFERENCE

How close did we get?

0 EXPERIMENTS
Joule, 1850 ± inferred 95% CI Modern reference Your trials
MODEL PREDICTIONCalculating…

Historical: 772.692 ± 4.3 ft·lbf/(lb·°F), with 95% interval inferred from 40 pairs—not published by Joule.

NUMERICAL VALIDATION

Three independent checks

LIVE
✓
Integrator versus closed formThermal solution / same parameters
0.000%
✓
Energy ledger closureWork − loss − stored heat
0.000%
✓
Monte Carlo versus noise law4,096 draws / predicted σ
0.000%
All three checks are within tolerance.
THE SCIENCE Equations, assumptions and original sources

Work of falling weights: W = 2mghN. After the pulley correction, the stirring power is P = (1 − f)W / t.

Heat balance: C dT/dt = P − k(T − Troom), with C = meq · 4184 J kg⁻¹ K⁻¹. The computed result uses fixed 2-second Euler steps; the independently evaluated closed form uses exp(−kt/C).

Mechanical equivalent: Jestimate = [Wstir − Qleak] / [1000meq ΔTobserved] in joules per thermochemical calorie. The room-exchange integral is calibrated in the model rather than estimated from a single thermometer reading.

Noise model: two independent normal thermometer errors with standard deviation σT (°F), one residual normal room-correction error σair (°F), then rounding to 0.005 °F. Thus σΔT ≈ √(2σT² + σair² + 0.005²/6). These assumptions are illustrative, calibrated to the observed scatter in Joule's control-paired series, not measured historical instrument distributions.

Historical reconstruction: Joule's 1850 water series used 40 stirring/control pairs; 20 successive falls of approximately 63 in per stirring run, two approximately 29 lb weights, a copper vessel, and a brass stirrer. Corrected mechanical work was 6067.114 ft·lbf per run, and corrected heating was 0.563209 °F; after the vacuum correction Joule reported 772.692 ft·lbf/(lb·°F). His paired data imply a statistical 95% interval of approximately ±4.3 ft·lbf/(lb·°F) under an independent-pairs model. Joule did not publish this interval.

Simplifications: Heat capacity is treated as constant; mixing is instantaneous; the falling weights deliver averaged power over 35 minutes; rope, pulley and bearing motion are not dynamically resolved; bath is reset between trials. The apparatus is a schematic reconstruction, not a dimensionally exact replica. Scene motion and water texture are illustrative. No association with a museum or historical estate is claimed.

Sources: J. P. Joule, “On the Mechanical Equivalent of Heat,” Philosophical Transactions 140 (1850), pp. 61–82, Tables I and IX; Science Museum Group, mechanical equivalent of heat apparatus, object 1876-492; American Physical Society, “June 1849” history article.
Made with 🤖 ChatGPT