Joule’s Paddle Wheel:
Turning Work into Heat
Two falling weights. A brass paddle in water. A temperature rise almost too small to see. Rebuild the measurement that linked motion and heat.
The weights are raised. Release them and watch their lost height warm the water.
The measured equivalent
*Interval estimated from Joule’s 40 published water trials; he did not publish this confidence interval.
Three ways to check the physics
Closed-form 2mghnη vs summed drops
Work vs stored heat + room transfer
Fixed-step dynamics vs analytic pulses
04 / BEHIND THE NUMBERSThe scienceEquations, measurement model and what is simplified+
Work of falling weights: W = 2 m g h N η. The two masses fall through height h, N times. The pulley factor η approximately accounts for Joule’s measured friction and string correction.
First law, including the room: C dT/dt = P(t) − k(T − Tₐ); C = (mwater + 0.2748 kg) × 4184 J/(kg·K). A falling mass powers the paddle over its descent; between falls the water exchanges heat with the room by Newton cooling. Each fixed timestep integrates the linear equation stably.
Measured constant: j = (W − Qroom)/(1000 × (mwater + 0.2748) × ΔTmeasured) in J/cal. The room correction is signed, so warmer air can add heat. The simulation uses the thermochemical definition of the calorie; Joule’s historical unit was the heat needed to warm one pound of water by one degree Fahrenheit near 55–60 °F.
Physical noise model: Each trial samples independent Gaussian thermometer errors on the before/after readings (user-selected one-reading rms, default 0.005 °F), quantizes readings to 0.005 °F, adds Gaussian 0.0015 °F drift over 35 minutes, 0.06% relative uncertainty in measured work, and 8% rms relative uncertainty in the room-heat correction. These stochastic widths are illustrative, not claimed to be Joule’s measured instrument error distribution. The 0.005 °F discernibility comes from Joule’s account.
Historical error bars: The grey dots derive from Table I’s forty reported friction runs. For each, its air/apparatus temperature difference and measured warming are used to reconstruct a corrected signal and relative work. A 95% confidence interval is calculated from the empirical scatter (Student t, 39 d.f.) and centred on Joule’s published pooled in-vacuo result. These are our derived uncertainty bars; Joule did not report modern confidence intervals.
Simplifications: Water is well mixed; the brass/copper container is represented as a constant water-equivalent heat capacity; g = 9.80665 m/s²; constant heat capacity and a linear room-loss coefficient replace temperature-dependent properties, mechanical transients and complex fluid flow. Paddle vortices are drawn for interpretation, not computational fluid dynamics. The real apparatus and correction are described in J. P. Joule, “On the Mechanical Equivalent of Heat,” Philosophical Transactions 140 (1850), pp. 61–82, Tables I and IX.