Pressure budget
Pressure vs. applied heat load · kPa
The operating point is marked. The crossing is the predicted capillary limit.
Thermal transport · Capillary-driven circulation
A loop heat pipe moves heat without a mechanical pump. Its porous wick creates the pressure that drives circulation — but every passage consumes part of that pressure budget. Tune the geometry and watch the operating margin change.
Pressure vs. applied heat load · kPa
The operating point is marked. The crossing is the predicted capillary limit.
Remaining pressure vs. heat load · kPa
Above zero: the wick can sustain circulation. Below zero: capillary dry-out is predicted.
The meniscus curvature in the wick produces a capillary pressure. Surface tension σ is in N m⁻¹, contact angle θ is 20°, and pore radius rp is in metres.
The porous wick uses Darcy's law. The liquid and vapour lines use laminar Hagen–Poiseuille flow. The elevation term is ρlgΔz.
The heat input becomes a latent mass flow using hfg. The capillary limit is the heat load at which pressure demand equals capillary supply.
Illustrative design values, fixed near-60 °C water properties, steady one-dimensional flow, constant properties, laminar circular lines, no local fittings, no boiling superheat, no sonic or entrainment limit, and no transient start-up effects. Vapour and liquid line losses are idealised.
Illustrative design, not affiliated with any real institution or manufacturer. Educational model — not a hardware design tool.