Governing equation
The one-dimensional model evolves water temperature with vertical diffusion and a uniform heat-loss term:
∂T/∂t = αeff ∂²T/∂z² − (T − Ta)/τ
Both tank ends have zero diffusive heat flux. A fixed-step finite-volume update uses no-flux boundary faces, so vertical diffusion redistributes heat without creating or destroying it.
What is measured
- Useful hot volume is the tank volume above the illustrative 50°C service marker.
- Thermocline width is the vertical distance between the 10% and 90% crossings of the current bottom-to-top temperature range.
- Stored heat is the sensible energy relative to the selected ambient temperature.
Constants and assumptions
Water heat capacity is approximated as 4,182 J/(kg·K) and density as 997 kg/m³ (textbook reference values near room temperature). Tank height 3.0 m, diameter 1.2 m, initial hot temperature 65°C, cool temperature 15°C, and the 50°C marker are illustrative. The effective diffusivity and heat-loss time constant are illustrative controls, not measured properties of a particular tank.
The model is height-only. It omits inlet jets, draw-off, buoyancy plumes, wall conduction, internal coils, variable water properties, and detailed room-side convection. The single time constant represents distributed heat loss. The diffusion test removes wall loss and uses an extended column so its front remains far from the ends.
The 50°C marker is an explanatory threshold only, not a safety recommendation or a specification for a real hot-water system.