W = (2 m g h n) × η
Two equal falling weights supply the work. The drive factor η = 0.995673 is calibrated to Joule’s pulley-friction and string-elasticity corrections at the historical setting.
Q = Ceq ΔT and J = W / Q
Ceq is the water-equivalent heat capacity of the water and metalwork. The result is expressed in foot-pounds per pound-degree Fahrenheit.
ΔTmeasured = ΔTtrue + k ΔTroom + ε
Noise model: ε is Gaussian trial scatter with σ = 0.03595 °F, estimated from the 40 raw gains in Joule’s Table I; the reading is then rounded to the selected thermometer step (historically 0.005 °F). Room drift uses Joule’s measured k = 0.04654 per °F per 35-minute trial. This empirical scatter is a lumped repeatability model, not a claim that every historical fluctuation was independent Gaussian noise.
Simplifications: the water and metalwork share one temperature; all corrected drive work becomes heat in the calorimeter; the calibrated drive factor is held constant when settings change; one displayed animation cycle represents the selected number of historical drops and is accelerated for the exhibit.
Independent educational reconstruction; not affiliated with the Royal Society or the Science Museum Group.