Geothermal Heat Flow and Well Power

1D crust conduction, geotherm and the power of a geothermal well.

Presets

Controls

Live readouts

Independent checks

Experiment

Run the experiment to find the depth of 150 C and check it numerically.
The science

Heat leaks upward from the Earth's interior by conduction (Fourier's law q = k dT/dz) and, in the crust, is topped up by the decay of uranium, thorium and potassium. In one dimension with uniform properties:

rho c dT/dt = k d2T/dz2 + A

  • Steady state with surface temperature T0, basal flux qb at depth L: T(z) = T0 + (qb + A L) z / k - A z^2 / (2 k). The surface flux is qb + A L.
  • Typical continental flux is about 65 mW/m2, giving about 25-30 K/km near the surface.
  • The model starts with cold rock and relaxes with diffusivity alpha = k / (rho c); the time scale of a 6 km column is L^2/alpha, about a million years (the time axis is accelerated and shown in kyr/Myr).
  • Power from a well: thermal P = m cp (Tw - Tr); the best any heat engine can do is Carnot 1 - Tc/Th (kelvin), and real binary-cycle plants reach very roughly half of that, assumed here as 50 %. Below 150 C use is mostly heating.

Honest simplifications: one-dimensional conduction only. No groundwater convection (which dominates in many fields), no heat transport by fluids in the rock, constant k and A, a fixed basal flux, no depletion of the reservoir by production, no pumping power or drilling cost. Parameter ranges are typical illustrative values, not a site model.

Checks shown in the page: the converged numerical profile against the analytic geotherm; an independent transient test against the exact solution dT erfc(z / (2 sqrt(alpha t))) for a suddenly heated half-space; surface flux against qb + A L; thermal power arithmetic.