EMBER EXCHANGE
Radiative view-factor laboratory
How much heat does a hot surface truly send to its neighbour? Shape the gap, steer a receiver, insert an opaque shield, examine surface finish, and track every watt through a thermal experiment.
The view-factor instrument
Measure how distance, offset and tilt change the fraction of radiation reaching the other plate.
Measurement curves
Click either static curve to set its experimental input. Move a pointer over a plot to inspect numerical values.
Field notebook
Save different configurations, compare their transfer rates and export the data with full experimental conditions and seed.
| Trial | Mode | Gap / m | Emissivity (hot) | F₁₂ | Pair W | Time / s |
|---|---|---|---|---|---|---|
| No measurements recorded yet. | ||||||
Laboratory assessment
The physics behind the glass
01 — What you are studying
Every object above absolute zero radiates electromagnetic energy. Yet a warm plate does not automatically deliver all its radiated power to an opposing surface. Some rays miss, some reach an intervening screen, and surfaces absorb only a fraction of the radiation incident upon them. This instrument investigates that geometry-dependent exchange in a large, black, isothermal enclosure.
The two square plates each measure 1.20 m across. The left plate normally heats the right. Their positions, angle, surface finish and temperatures are fully coupled to the calculations. The coloured receiver tiles are a map of physical local view factor, not a decorative temperature animation; warmer colours identify locations with better geometric sight of the source.
02 — Controls and navigation
Drag the green handle to translate the receiving plate in the horizontal plane. Its amber handle alters tilt. Switch on the screen and pull its orange handle to pass a real opaque obstruction through the viewing rays. Slide the source's orange handle vertically to set temperature. Move the white microbolometer on the receiving face to inspect local flux. Use drag on empty space to orbit, mouse wheel or a two-finger gesture to zoom, and the view buttons to restore known camera angles. All parameters also have keyboard-operable sliders.
The Run button activates the energy balance, with adjustable time scale. Record any result in the notebook, examine either graph and export a CSV for analysis. Selecting a ready-made preset restores a valid apparatus configuration.
03 — The law that governs the field
The Stefan–Boltzmann law states that an ideal black surface emits E = σT⁴ watts per square metre, where σ = 5.670374419 × 10⁻⁸ W m⁻² K⁻⁴. Radiation depends on absolute temperature to the fourth power. This is why doubling Kelvin temperature multiplies blackbody emission by sixteen, not two.
For two small diffuse patches, their mutual geometric contribution obeys dF₁₂ = (cos θ₁ cos θ₂ / πr²) dA₂. Here r is the separation between the patches and each θ measures the ray direction relative to the patch normal. The laboratory numerically integrates this kernel over the two finite square surfaces. Rays are rejected if they point behind a plate or strike the opaque internal screen.
A view factor is dimensionless and bounded by zero and one. Reciprocity demands A₁F₁₂ = A₂F₂₁. Because the two plates have equal area here, their integrated factors agree. A local probe value can differ greatly from that area average: a plate edge can receive less illumination than its centre.
04 — Reflections and radiosity
Real materials emit and absorb imperfectly. For an opaque diffuse-grey surface, emissivity ε is also absorptivity at the model's effective thermal wavelength range. Its total departing radiation is called radiosity, J = εσT⁴ + (1−ε)G, where G is incoming irradiance. In this enclosed setup, G₁ = F₁₂J₂ + (1−F₁₂)σTₐ⁴ and a corresponding equation holds for the receiver. Solving the coupled two-by-two system includes repeated reflection between the panels and irradiation from the ideal black ambient walls.
The total radiative heat leaving plate 1 is Q₁ = A₁(J₁−G₁). The specifically exchanged power along their mutual view is Q₁₂ = A₁F₁₂(J₁−J₂). Do not confuse this with total source loss: much radiation reaches the surrounding enclosure instead.
05 — Five investigations to try
Geometry: Begin with equal height, aligned faces and no screen. Change only gap distance. Predict a decreasing view factor; compare the measured F₁₂ with the complete distance scan, then tilt the receiver and see why projected area matters.
Shadows: Centre the black stop and measure the reduced view factor. Slide it away without changing either plate temperature. Confirm that geometric interception changes the heat received even though the radiating source itself is unchanged.
Surfaces: Use a close-facing arrangement. Change the two emissivities from near-black to reflective. Predict reduced mutual exchange, but also inspect total radiative loss and the large black environment's compensating contribution.
Transient: Choose a finite heater power and press Run. Time-step integration evaluates both surface balances, accounting for heater input, outgoing radiation and linear ambient heat leakage. Ask how the two heat capacities and leakage coefficients affect the response time. A zero-power cooldown is available as a preset.
Field survey: Move the receiver's microbolometer from centre to edge and near a partial shadow. Compare local probe flux with global pair exchange; one point reading does not equal the integrated average over 1.44 m².
06 — Why engineers care
View factors and radiosity are important in furnace design, satellite thermal control, radiative shields, infrared calibration and temperature-sensitive manufacturing. An optical line of sight is not a sufficient heat-transfer calculation: emitting directions, target orientation and surface optical properties all matter. Thermal engineers routinely use geometric integrations similar to this virtual bench, along with enclosure radiation methods, to predict energy flow.
07 — Model boundaries
Both panels are assumed flat, perfectly isothermal, opaque and diffuse-grey. Each emits in every outward direction according to Lambert's cosine law. The enclosure is a large ideal black surface at a prescribed constant temperature; the movable screen absorbs intercepted radiation and is treated as part of that ambient boundary. There is no diffraction, polarisation, wavelength-dependent emissivity, re-emission from a heated baffle, edge reflection, conduction through supports or gas-radiation coupling. Plate temperature stays spatially uniform even while the receiver has a nonuniform incident heat map.
Finite-area view factors are evaluated by midpoint quadrature. Local plots and the detailed heat map use finite grids, so small errors are possible at abrupt shadow boundaries. The transient uses a bounded Heun integrator, a linearised phenomenological ambient heat-leak term, and constant heat capacities. Neither the source's orange glow nor the highlighted ray segments is a calibrated optical spectrum or an exact photon count; path segments are illustrative samples of unobstructed rays from the real geometric model. The 3D apparatus is shown at approximate metre scale with exaggerated handle sizes for accessibility.
08 — Glossary and deeper questions
View factor: fraction of diffuse radiation emitted by one surface that arrives directly at another. Radiosity: emitted plus reflected flux departing a surface. Irradiance: arriving radiative power per unit area. Emissivity: ratio of a real surface's emission to a blackbody at the same temperature. Kelvin: absolute temperature unit. Thermal capacity: energy required for one Kelvin of bulk temperature rise. Radiative equilibrium: no net change in stored thermal energy from the balance of heat flows.
For further exploration, test reciprocity through the whole tilt range, compare the ideal blackbody case to mixed emissivities, and determine whether blocking half the receiver's visible area halves total coupling (it generally does not). Explain why increasing receiver temperature can reverse net transfer without changing the view factor.