FIELD NOTES SPACE SYSTEMS
MY SIMULATOR / LIFE SUPPORT
INTERACTIVE LAB ILLUSTRATIVE MODEL
WATER RECOVERY / CABIN AIR

Dew-point recovery

Cool the circulating air. Watch invisible vapour become collected water.

RECOVERY ACTIVE
RENDER
i

The coil is below the dew point. Water vapour condenses on its surface and drains into the recovery tank.

LIVE TELEMETRY

What the loop is doing

ALL VALUES ILLUSTRATIVE
CABIN DEW POINT °C
16.1°C
Calculated from vapour pressure
WATER CAPTURE RATE g/h
1,240g/h
Liquid leaving the coil
CABIN RELATIVE HUMIDITY %
65%
Current vapour / saturation
RECOVERED WATER g
0g
Collected since reset
MODEL INTEGRITY
Independent checksCompared at the current state
Dew-point inversion0.000%
Closed form vs numeric bisection · % difference · illustrative
Vapour inventory0.000%
Ideal gas vs humidity-ratio path · % difference · illustrative
Water ledger0.000%
Initial + generated vs stored + recovered · % difference · illustrative
BENCH EXPERIMENT · ILLUSTRATIVE

How much water can this loop collect?

Run a simulated ten-minute collection test from the current cabin state. The measured result is compared with a finer-step integration of the same governing equations as a theory reference.

RESULTS WILL APPEAR HERE
∑The scienceEquations, assumptions and model limits⌄

Textbook relationships

Saturation vapour pressure uses the Magnus approximation, with temperature in degrees Celsius:

psat(T) = 610.94 exp(17.625 T / (T + 243.04)) Pa

Water-vapour pressure is pv = RH · psat(T). The dew point is the temperature at which saturation pressure equals pv. The cabin vapour inventory follows the ideal-gas relation:

mv = pv V / (Rv TK)

Here Rv = 461.5 J/(kg·K), Rda = 287.05 J/(kg·K), and the humidity-ratio coefficient is 0.62198. These are textbook reference constants and approximations.

How the condenser is modelled

The humidity ratio is w = 0.62198 pv/(P − pv). If the coil is colder than the dew point, its saturated humidity ratio wsat,coil is lower than the inlet value. A single-pass effectiveness ε gives:

wout = win − ε max(0, win − wsat,coil)

The recovered-water rate is dry-air mass flow multiplied by (win − wout). Cabin vapour mass then follows dM/dt = moisture load − recovered water. The state is integrated with fixed-step fourth-order Runge–Kutta; the displayed time acceleration changes simulated seconds, not the integration step.

Simplifications and illustrative settings

The cabin is a well-mixed, fixed-volume vessel at a constant temperature and textbook standard reference pressure of 101,325 Pa. Airflow, coil temperature and collection effectiveness are held constant between user changes. The model assumes a liquid drain, no ice formation, no fan heating, no pressure-control dynamics, no latent-heat feedback, and no detailed cabin-surface sorption. At the illustrative 99.5% relative-humidity ceiling, additional water is recorded as a simplified surface film so the water ledger remains closed.

The 80 m³ cabin, scenario values, moisture loads, coil effectiveness, visual dimensions and time acceleration are illustrative or scaled—not spacecraft design specifications. The Magnus relation is an approximation over the model's operating range. The simulation is educational and is not a certified environmental-control design tool.

FIELD GUIDE · SPACECRAFT ENVIRONMENTAL CONTROL

Why a cold surface can turn cabin humidity into a resource

Water vapour is part of the cabin atmosphere, but it does not have to remain there. A condenser can remove it from recirculating air, collect it as liquid and send it into a recovery loop. The key threshold is the dew point: the temperature at which the air's current water-vapour content reaches saturation.

Change the cabin humidity or coil temperature, then watch the dew-point margin, collection rate and water inventory respond. The model separates the physical relationships from the illustrative spacecraft-scale settings.