MYSIMULATOR • SCIENCE EXHIBITSTHERMODYNAMICS
Heat transfer / interactive laboratory

Coupled Thermal Masses: The Heat Exchange Laboratory

Quality
SCHEMATIC · scaled geometry
Block A · model—
Block B · model—
Heat flow A → B—
Elapsed · model—

Numerical cross-checks

Computed vs textbook solution / balance; tolerance 0.01%
Weighted mean temperature—
Temperature difference—
Energy accounting—

Experiment · half the difference

Theory: — · Measured: —

—

Illustrative task: halve the initial gap within 60 model s.
The science

Cₐ dTₐ/dt = −G(Tₐ−Tᵦ) − λCₐ(Tₐ−Troom)
Cᵦ dTᵦ/dt = +G(Tₐ−Tᵦ) − λCᵦ(Tᵦ−Troom)

M = (CₐTₐ+CᵦTᵦ)/(Cₐ+Cᵦ); D = Tₐ−Tᵦ
M(t) = Troom + (M₀−Troom)e^(−λt)
D(t) = D₀e^(−kt), k = G(1/Cₐ+1/Cᵦ)+λ
t½ = ln(2)/k

Textbook lumped-capacitance energy balance with an illustrative equal fractional leakage rate. Temperatures use Celsius; temperature differences use kelvin. Each block is internally uniform, the bar stores no heat, conductances and heat capacities are constant, and radiation and phase changes are excluded. The model uses fixed-step fourth-order Runge–Kutta integration (0.05 model s); loss is integrated as an independent energy ledger. Relative differences use a small absolute reference floor (1 K or 1 J) near zero. Geometry, colour shading and moving heat markers are illustrative, not a thermal camera or individual particle trajectories.

Independent educational exhibit; not affiliated with a laboratory or equipment manufacturer.

Made with 🤖 ChatGPT