Coupled Thermal Masses: The Heat Exchange Laboratory
Numerical cross-checks
Experiment · half the difference
Theory: — · Measured: —
—
The science
Cₐ dTₐ/dt = −G(Tₐ−Tᵦ) − λCₐ(Tₐ−Troom)
Cᵦ dTᵦ/dt = +G(Tₐ−Tᵦ) − λCᵦ(Tᵦ−Troom)
M = (CₐTₐ+CᵦTᵦ)/(Cₐ+Cᵦ); D = Tₐ−Tᵦ
M(t) = Troom + (M₀−Troom)e^(−λt)
D(t) = D₀e^(−kt), k = G(1/Cₐ+1/Cᵦ)+λ
t½ = ln(2)/k
Textbook lumped-capacitance energy balance with an illustrative equal fractional leakage rate. Temperatures use Celsius; temperature differences use kelvin. Each block is internally uniform, the bar stores no heat, conductances and heat capacities are constant, and radiation and phase changes are excluded. The model uses fixed-step fourth-order Runge–Kutta integration (0.05 model s); loss is integrated as an independent energy ledger. Relative differences use a small absolute reference floor (1 K or 1 J) near zero. Geometry, colour shading and moving heat markers are illustrative, not a thermal camera or individual particle trajectories.
Independent educational exhibit; not affiliated with a laboratory or equipment manufacturer.