Coal Stockpile Self-Heating: Arrhenius Source and Frank-Kamenetskii Criticality

Cut a coal heap open and watch it warm: oxidation heat against conduction and air loss decides whether it levels off or runs away to ignition.

Switch to 2D

Presets

Playback

Parameters

Camera

Layers

Quality

Model check

The science

What you see. A coal stockpile cut open along its centre. The flat face is coloured by the temperature inside (dark blue = air temperature, orange = hot, white-yellow near ignition, with a faint isotherm every 20 K). Coal slowly oxidises in air, and the heat it makes can only leave by conduction through the heap; whether a pile stays warm or runs away to ignition depends on its size.

Heat balance. For a hemispherical pile on an insulating base (a sphere by mirror symmetry): ρcp ∂T/∂t = (k/r²) ∂/∂r (r² ∂T/∂r) + φ(r) q(T), with an Arrhenius source q(T) = q30 exp[(E/R)(1/303.15 − 1/T)] and surface loss −k ∂T/∂r = h (T − Ta). The factor φ(r) = exp[−(R − r)/L] says oxygen reaches the interior only over a penetration depth L, so the hot spot settles below the surface rather than at the centre. The ODEs are solved by implicit finite volumes with the source linearised.

Criticality. Frank-Kamenetskii (1939) showed that a steady state exists only if δ = (E/R Ta²) q(Ta) R²/k is below a critical value δcr: 0.878 for a slab, 2.00 for a cylinder, 3.322 for a sphere with a perfectly cooled surface, and less for finite surface loss (Biot number Bi = hR/k). The simulator evaluates δcr(Bi) from the steady-state ODE u″ + (n−1)u′/s + eu = 0 as the maximum of s² exp(u + s u′/Bi). Above it the temperature runs away: because q roughly doubles per 10 K, doubling the radius multiplies δ by four.

Honest simplifications. One-step Arrhenius oxidation with an invented reactivity (real coals span orders of magnitude and change as they age); no moisture evaporation and condensation (which can dominate the early warming), no convective air flow driven by buoyancy or wind, no layering, no spontaneous-combustion index tests. The hemisphere stands in for a conical pile. The ignition threshold (200 °C) is a marker, not a combustion model. Use it to see how size, wind cooling, air access and reactivity combine, not to certify a stockpile.

Checks. (1) δcr for slab, cylinder and sphere from the ODE against the classical values; (2) the finite-volume scheme against the exact steady state of a uniformly heated sphere; (3) the discrete energy balance (generated = lost + stored); (4) the critical pile radius from transient simulations against the Frank-Kamenetskii theory with the Biot correction.

Loading model...
Loading Blender model...
Temperature profile through the pile
Hottest point over time
Stability map: delta against Biot number
Made with 🟠 Blender · Three.js