Capillary Shift: Design a Stable Heat Pipe
A design brief from the thermal lab: carry 1.20 kW while keeping at least 25% capillary-pressure reserve.
STEADY-STATE MODEL
ENGINE v1.0 · SEED 641827
Carry 1.20 kW with a 1.25× reserve
Maintain a capillary limit of at least 1.50 kW at the selected orientation.
The science / assumptions
The capillary limit is the positive heat load at which ΔPcap − ΔPgravity = ΔPl + ΔPv. Water properties vary with temperature using compact correlations; saturated vapour is treated as an ideal gas. Vapour friction uses laminar Poiseuille-equivalent Darcy friction below Re 2,300 and a smooth-pipe Blasius fit above Re 4,000, with a linear transition between them. Contact angle is fixed at 20°; the outer radius is 6 mm; the wick flow area is the annulus between the wall and vapour core.
Illustrative, steady, one-dimensional model. It omits sonic choking, entrainment, boiling and viscous limits, local bend losses, non-condensable gases, and detailed two-phase wick microstructure. Property fits and geometry are educational approximations, not a product rating. The independent readout is a second root solution using the Illinois false-position method; the primary limit uses bounded bisection.
Illustrative design, not affiliated with any real institution or manufacturer.
Reading the instrument
Submit a wick design that meets the required heat load and reserve ratio without exhausting the pressure budget. Values are model outputs. Compare the current load with the independently solved capillary limit; a pressure margin below 1.00 indicates the simplified return path cannot sustain the selected load.