Trace the vapour core, porous wick and liquid return path. Adjust the pore scale and orientation to see where the pressure budget is spent.
Water properties are held at their 60 °C reference values; geometry and operating conditions are illustrative.
Heat evaporates liquid at the hot end. Vapour travels through the open core, condenses at the cold end, and returns through the porous wick under capillary pressure.
The meniscus pressure must overcome wick friction, vapour friction and any adverse gravity head. A positive reserve means this reduced-order capillary condition is satisfied.
The capillary pressure is set by surface tension, wetting and mean pore radius. A finer pore raises the pressure ceiling, but commonly reduces permeability; this module isolates those effects one parameter at a time.
Assumptions: steady one-dimensional transport; uniform saturated water properties at 60 °C; cylindrical laminar vapour core; Darcy flow through a homogeneous wick; constant effective length; no sonic, boiling, entrainment or viscous limit. Positive inclination places the condenser above the evaporator. Values are illustrative, not a design certification.
Independent numerical check: the displayed energy-closure readout reconstructs heat rate from ṁ × hfg and compares it with the entered heat load.
Illustrative design, not affiliated with any real institution or manufacturer.