Design a compact wick that transports 750 W against a 60° upward lift with at least 15% capillary reserve. Adjust the geometry; the target stays fixed.
Keep the wick compact while maintaining a positive pressure margin. The target is a minimum reserve of 15% of the capillary pressure ceiling.
Hint: increasing permeability and wick area reduces liquid pressure loss. A finer pore increases capillary pressure, but may reduce permeability in real materials.
Water properties are held at their 60 °C reference values; geometry and operating conditions are illustrative.
This challenge evaluates the same steady capillary pressure balance at a fixed heat rate and inclination. The score rewards meeting the reserve target and then favours a smaller combined wick-flow area and vapour-core cross-section. The score is a teaching rubric, not an engineering optimisation metric.
Assumptions: steady one-dimensional transport; uniform saturated water properties at 60 °C; cylindrical laminar vapour core; Darcy flow through a homogeneous wick; constant effective length; no sonic, boiling, entrainment or viscous limit. Positive inclination places the condenser above the evaporator. Values are illustrative, not a design certification.
Independent numerical check: the displayed energy-closure readout reconstructs heat rate from ṁ × hfg and compares it with the entered heat load.
Illustrative design, not affiliated with any real institution or manufacturer.