CAPILLARY HEAD
ΔPcap = 2σ cos θ / rpVAPOR GENERATION
ṁ = Q / hfgWICK PRESSURE LOSS
ΔPw = μ Lw ṁ / (ρ K Aw)LINE PRESSURE LOSS
ΔP = f (L / D) ρu² / 2Illustrative water properties are fixed at 60 °C. The steady model omits gravity, local fittings, vapor compressibility, contact-angle hysteresis and start-up transients. A positive capillary reserve indicates a feasible pressure budget within these assumptions; it is not a certified operating envelope.