Effects shown are noiseless model estimates for this setup. Friction is omitted because this calorimetry setup has no sliding contact in the measurement. Toggle any combination, then run to see the combined effect.
The science
Calorimetry uses conservation of energy: energy released by the warmer metal is gained by the water and calorimeter, with real-world losses treated as experimental error.
Governing equation
For an ideal insulated system:
m_m c_m (T_m − T_f) = (m_w c_w + C_cal)(T_f − T_w)
Rearranging gives the sample's specific heat:
c_m = [(m_w c_w + C_cal)(T_f − T_w)] / [m_m(T_m − T_f)]
Graph variables: x = m_m(T_m − T_f), y = (m_wc_w + C_cal)(T_f − T_w). The least-squares gradient through the origin is cₘ.
Assumptions
- Water and calorimeter form one well-mixed thermal node.
- The aluminium sample has uniform temperature and constant specific heat of 897 J/(kg·K).
- The calorimeter heat capacity is known: 28 J/K.
- Water specific heat is 4180 J/(kg·K); evaporation and splashing are ignored.
- Five bath temperatures provide a range of energy-transfer points.
- 3D scene geometry uses a 0.2 m per scene-unit scale; the bench is approximately 2.16 m × 1.26 m.
Measurement precision and noise
- Digital balance: 0.1 g resolution, ±0.1 g stated accuracy; seeded Gaussian σ = 0.05 g.
- Thermometer: 0.1 °C resolution, ±0.2 °C stated accuracy; seeded Gaussian σ = 0.12 °C.
- Stopwatch: 0.1 s resolution, ±0.2 s stated accuracy; seeded Gaussian σ = 0.1 s.
- Noise is repeatable for a given seed and quantised to the displayed instrument resolution.
Fixed-step model and uncertainty
The thermal exchange uses an explicit two-node model with a fixed time step of 1/120 s. The fitted uncertainty is a conservative 1σ standard uncertainty: the larger of the regression standard error and a 1.1% instrument-resolution floor. The browser self-test checks the noiseless result against the closed-form energy balance and runs 200 seeded noisy fits.