A negative probe repels electrons and collects ions; a positive one collects electron current.
Measurement
Model checks
The science
What is modelled
An idealised collisionless, unmagnetised Maxwellian plasma and a small planar probe. Below the plasma potential Vp the electron current falls exponentially; above it, it saturates. Ions give a small, nearly constant current set by the Bohm criterion.
Equations
- Electron current
Ie = Ies exp((V - Vp)/Te)for V < Vp, withIes = e n A sqrt(kTe / 2πme). - Ion saturation
Iis = 0.61 e n A sqrt(kTe/mi)(Bohm). - Floating potential
Vf = Vp + Te ln(Iis/Ies); Debye lengthλD = sqrt(ε0 kTe / n e2).
Honest limits
Teaching-grade model: no magnetic field, collisions, sheath expansion or RF; the fit is not uncertainty-calibrated. The sheath circle is a schematic, not to scale.
What to try
- Pick Helium, hot electrons: the semilog slope flattens as Te rises and the Debye length grows.
- Raise the noise to 5 percent and see how the fitted Te and density degrade.
- Move the bias below the floating potential and watch the net current turn negative (ions dominate).