The gate was designed by Carl Gotthard Langhans and built in 1788–1791. Its flanking open colonnades belong to a later alteration.
Science, equations and limitations
Vertical dead load: F = ρVg, with ρ = 2,200 kg/m³ and V = 420 m³ (illustrative equivalent upper stone volume).
Added test load: Fₜ = mg; average column reaction R = (F + Fₜ)/12.
Mean axial pressure: σ = R / A where A = πd²/4; d = 1.75 m (published column diameter at base). Ignores taper and local contact.
Solar altitude: sin α = sin φ sin δ + cos φ cos δ cos H, latitude φ = 52.52°; H = 15° × (solar time − 12). Declination δ uses approximate solstice/equinox values.
Shadow reach: L = h / tan α for α > 0; uses h = 20.3 m (architectural body, excluding quadriga).
Independent check: Compare the engine's summed column reactions to the separately evaluated total vertical weight.
This educational model does not calculate historic structural stresses, foundation settlement, bending, lateral action, masonry joints or solar obstruction by surrounding buildings.
Documented: overall dimensions, Doric colonnade, five passages, quadriga and principal dates. Scholarly reconstruction: sectional grouping and simplified assembly order. Artistic interpretation: fine reliefs, patina, figures, exact block joints, surface wear and the historical setting.
Educational reconstruction; details marked as reconstruction are interpretive.