Drag the blue hand controller | drag the white port ring | click a numbered target for auto-reach | orbit with empty-space drag

Teleoperated Surgical Robot

Scenarios

Live readouts

Hand vs tool-tip jitter and tissue force

Controls

Quality

Model checks

The science

Remote centre of motion (RCM). A laparoscopic shaft passes through a small port in the abdominal wall, which acts as a fixed pivot. For hand position H and port P the shaft lies on the line through H and P, so the tip moves opposite to the hand, scaled by the lever ratio din / dout (inside length over outside length). A robot enforces the same constraint in software or with a parallelogram linkage, so the pivot stays at the port even when the port is moved.

Motion scaling and tremor filtering. The robot multiplies the hand motion by a scale factor (1/3 gives 3:1) and passes it through a first-order low-pass filter with cut-off fc: y ← y + a (u − y), a = 1 − exp(−2π fc Δt). A sinusoid of frequency f is attenuated by about 1 / √(1 + (f/fc)2), so 8–12 Hz physiological tremor is cut by 80 percent or more at fc = 2 Hz, while slow intended motion passes. The price is lag, which adds to the control latency.

Tissue contact. The tissue is a linear spring, F = k x for penetration x; a force above 4 N counts as trauma in the task score. The haptic gain g scales the penetration by 1 − 0.45 g; this factor is a game-design approximation of the surgeon feeling resistance, not a measured quantity. The safety limit clamps the force.

Honest simplifications. Tremor is a sum of fixed sinusoids, not a recorded signal; tissue is a single linear spring without viscosity, adhesion or tearing; the arm is a two-link inverse-kinematics drawing (its joints do not limit the motion); instrument wrist and jaw dynamics, port friction and abdominal wall deformation are not modelled. This is an educational model, not a clinical device.

Checks. (1) the shaft always passes through the port and the tip moves by the lever ratio; (2) the filter gain at 10 Hz against the exact discrete-time formula and the continuous one; (3) Hooke's law, the force limit and the trauma threshold; (4) the tremor amplitude after filtering against the sum of per-tone gains, and steady motion scaling.

Remote centre of motion: the shaft pivots about the fixed port, so a manual lever inverts and scales motion by (insertion depth / outside length). Robot mode applies motion scaling and a first-order low-pass filter to the hand signal (physiological tremor ~8-12 Hz). Tissue contact: F = k x penetration; force over 4 N counts as trauma. Educational model, not a clinical device.
Made with 🟠 Blender · Three.js