Cobot Contact Limits: ISO/TS 15066 Force, Pressure and Safe Speed

A collaborative-robot test cell built in Blender: an arm touches a test dummy, a glowing marker shows force against the body-region limit. Drag to orbit.

Switch to 2D
Controls

Presets

Parameters

Quality

Camera

Model checks

The science

What is being tested. In a collaborative (power-and-force-limiting) cell a person may be touched by the robot. ISO/TS 15066 does not forbid contact; it limits the force and pressure that each body region may receive. A region has a quasi-static force limit (clamped, the body cannot escape) and a pressure limit; for a free, transient impact the tabulated values may be doubled. Skull, forehead and face contact is to be avoided altogether in real installations.

Annex A impact model. The robot (effective mass mR = M/2 + mL, half the moving mass plus the payload) and the body region (effective mass mH) are two free bodies that touch through a linear spring of stiffness k (the soft-tissue stiffness of that region). With reduced mass μ = mRmH/(mR+mH) the energy balance ½μv² = F²/(2k) gives Fmax = v√(kμ). The contact lasts tc = π√(μ/k) and the force is a half-sine; the impulse is 2μv. Peak pressure is p = Fmax/A for a contact area A. Inverting gives the permitted speed vmax = min(Flim, plimA)/√(kμ); a sharp tool (small A) is pressure-limited, a padded link is force-limited.

Speed and separation. If the robot instead stops before touching, the protective separation distance is Sp = vh(Tr+Ts) + vrTr + vr²/(2a) + C with the stopping time Ts = vr/a and an intrusion allowance C (here 0.1 m). The checks integrate both models numerically (RK4 for the impact, a 0.1 ms time loop for the stop) and compare with the closed forms, with the elastic-collision velocity formulas and with the inversion vmax.

Simplifications. One-dimensional contact with a linear, lossless spring (real tissue is non-linear and dissipative, so the true peak is a little lower); the human region is free (no attached body mass beyond mH); the robot's deceleration is constant; sensor and position-uncertainty margins (Zd, Zr) are folded into C. The body-region values are the commonly reproduced ISO/TS 15066 Annex A figures and are illustrative: use the current standard and a measured collision test for a real risk assessment. Deformation in the animation is exaggerated for visibility. This is an educational model, not safety advice, and not affiliated with any robot maker.