Vacuum Gripper Pick and Place

Holding force, leaks and slip limits of a suction cup.

Switch to 3D

Presets

Playback

Cup and pump

Size, pump speed and how leaky the surface is.

Part

Mass and surface friction.

Robot

How hard the gantry accelerates.

Layers

Model checks

The science

Vacuum and holding force

A cup of diameter d on a part with vacuum dP below atmosphere presses with F = dP x pi d^2 / 4. A 30 mm cup at 84 kPa holds about 59 N. The vacuum cannot exceed the atmosphere (about 101 kPa), and with a pump that reaches 85 kPa the usable level also depends on leakage.

Pump against leak

The cup, tube and manifold hold a small volume V. The pump removes free air at speed S while a leak of conductance C lets air back in (about 0.2 L/s per mm2 of leak area for a choked orifice, order of magnitude): V dp/dt = -S (p - p_u) + C (p_atm - p). The vacuum therefore rises like dP(t) = dP_ss (1 - e^(-t/tau)) with dP_ss = 85 kPa x S/(S + C) and tau = V/(S + C). A porous cardboard surface acts as a big leak and lowers the steady vacuum.

Lifting and sliding

During a lift at acceleration a the cup must carry m (g + a), so the vertical safety factor is F / (m (g + a)) and the heaviest part is F / (g + a). In a horizontal move the load hangs below the cup, the clamping force on the contact is F - m g and friction coefficient mu must resist the inertia m a: safety factor mu (F - m g) / (m a), heaviest part mu F / (a + mu g). Industrial practice asks for a safety factor of about 2 or more; the page uses 2 for the rated payload.

The cycle

Approach, descend, evacuate until the cup can hold, lift with a bang-bang acceleration (accelerate for half the time, brake for half), traverse 0.8 m the same way, lower, vent and return. The part is checked at every time step; the first moment the vacuum force or friction is not enough it drops or slides.

Simplifications

Rigid part and ideal seal, one cup, a leak that does not change during the cycle, no cup deformation or tilting torques, constant friction, no air-flow pulsations and a single linear pump model. Use it for the trends, not for dimensioning a real gripper.

What to try
  1. Watch the default cycle: vacuum builds in about 15 ms, then the box lifts and traverses with a safety factor of 4.
  2. Press the heavy box preset: the safety factors fall toward 1 and the readouts show which limit is hit first.
  3. Press the fast robot preset: the part slides sideways during the traverse although the lift limit is fine.
  4. Press the porous cardboard preset: the leak lowers the vacuum and the holding force, and the cycle takes longer to build vacuum.
  5. In the acceleration graph find the acceleration where the sideways safety factor crosses 1.
Vacuum build-up after the cup touches the part
Heaviest part against cup diameter
Safety factors against robot acceleration
Holding force against leak area