Controls
Presets
Parameters
Model checks
The science
Setup. A disc of radius R and mass m is held by two point fingertips at polar angles θ and π − θ (θ > 0 above the equator). Each fingertip pushes with a normal force Ni (towards the centre) and a tangential friction force fi. Coulomb friction limits |fi| ≤ μ Ni: the contact force must stay inside the friction cone of half-angle α = atan μ around the normal.
Force closure. For two frictional point contacts the grasp resists any wrench (it is in force closure) exactly when the line joining the contacts lies inside both cones (Nguyen 1988). On a disc the angle between that chord and the normal is |θ|, so the criterion is |θ| < atan μ. The page checks it independently: the four cone-edge wrenches (Fx, Fy, τ/R) positively span the plane exactly when their one-dimensional null-space vector has components of a single sign.
Holding a load. With the weight m ge (ge = g + a during a lifting acceleration a) acting at a centre of mass offset by e R, equilibrium of forces and of torque about the centre of mass plus the squeeze condition NR + NL = 2N is a 4 x 4 linear system for (NR, fR, NL, fL). The four cone inequalities are linear in N, so the feasible squeeze is an interval [Nmin, Nmax]. At θ = 0, e = 0 it reduces to the textbook Nmin = m ge/(2μ). A grasp below the cone (θ < −atan μ) can carry the weight with the normals alone but has a finite Nmax: squeezing harder pushes the object out. Above the cone no squeeze works.
Slip. If the static condition fails, the object slides along the pads with kinetic friction μk = 0.85 μ: d¨ = ge − 2 N(μk cos θ − sin θ)/m. The checks compare the closed-form interval with a brute-force scan of the matrix solution, the textbook limit, the sliding distance with its formula, the scaling with lift acceleration, the cradle window and the equilibrium residual about a different reference point.
Simplifications. Planar (the third dimension and rolling resistance are ignored), rigid bodies, point contacts with no torsional (soft-finger) friction, the same μ at both contacts, a symmetric gripper that sets equal mean squeeze, and a contact geometry that does not change while the disc slides a few millimetres. The lift is shown as one accelerating stage (load g + a for 0.45 s) followed by constant velocity. Real fingertips are compliant and their friction depends on the normal load, speed and surface.