The science
What is modelled
A lipid nanoparticle (LNP) carrying gene-editing cargo is injected into the blood and reaches a liver sinusoid, a capillary whose wall (the endothelium) is pierced by fenestrae grouped in sieve plates. To work, a particle must drift to the wall, squeeze through a fenestra into the space of Disse, pick up the protein ApoE, be taken up by a hepatocyte through the LDL receptor, and finally escape the acidifying endosome before the lysosome destroys it. The simulation follows every particle through those steps with random motion and chance, and shows the yield that emerges from the chain.
Equations
- Transport: Poiseuille flow
u(r) = 2 U (1 − r²/R²)carries the particle along while Brownian motion with the Stokes–Einstein coefficientD = kBT / (3 π η d)moves it sideways. The vessel is drawn about six times shorter along the flow than a real 250 µm sinusoid, with the true radius of 5 µm, and particles enter with flux-weighted positions. - Sieving: sieve plates cover about 30 % of the wall and pores take about 22 % of a plate. A particle touching a plate crosses with the hazard
ν ε Ks, whereKs = (1 − d/dpore)²is the steric partition: the centre of a sphere must lie within a distance dpore/2 − d/2 of the pore axis. Larger than the pore, nothing passes. - Corona and uptake: PEG-lipid slowly leaves the particle, letting ApoE bind:
θ = 1 − exp(−ln2 · t / t1/2)with t = 30 min in the blood. Endocytosis needs the particle to fit a coated pit, modelled by1 / (1 + exp((d − 150)/20)). - Charge: the ionizable lipid is protonated according to
f+ = 1 / (1 + 10pH − pKa)(Henderson–Hasselbalch). A lipid that is cationic at pH 7.4 shortens circulation,survive = exp(−kc f+(7.4)), but a lipid that is not charged in the endosome cannot disrupt its membrane. - Endosome: the pH falls as
5.0 + 1.5 exp(−t/12 min). The escape hazard iske f+(pH(t))and lysosomal degradation has the hazard kd, soPesc = ∫ h exp(−∫(h + kd)). With the chosen constants a few percent of internalised particles escape, the same order as published measurements of LNP escape. - Loading: a particle holds cargo with probability
EE = 1 − exp(−(N/P)/1.2).
Checks run in the page
- The Stokes–Einstein coefficient for a 100 nm particle is compared with its known value (about 3.8 µm²/s), and thousands of random walkers using the page’s own Brownian step are compared with the mean-square displacement 6 D t.
- The steric partition is verified by throwing random points at a pore, and the Renkin hindrance factor is checked to fall monotonically from 1 to 0.
- The escape probability from integrating the hazards is compared with a Monte Carlo of tens of thousands of endosomes using your pKa, and with the closed form for a constant hazard.
Honest simplifications
- The rate constants (ν, kc, ke, kd), the pit-fit curve, the plate coverage and the 30 min ApoE time are illustrative values chosen so that the stages have realistic orders of magnitude, not fitted to one study. Reports on ionizable lipids find an optimum apparent pKa around 6.2–6.5 for liver siRNA delivery and slightly higher for mRNA; the optimum in the pKa graph comes from the balance of clearance against escape in this model and is a qualitative echo of that, not a prediction.
- Wall drag on a particle near a pore, convective flow through the fenestrae, endothelial transcytosis, Kupffer-cell capture, particle aggregation and the shedding of the lipid coat during circulation are not modelled. The sieving uses the steric partition only; the full Renkin factor is shown for comparison.
- Particles are drawn about six times larger than real so that you can see them, and the endosome clock runs much faster than real time (30 minutes of endosome time per second at the default speed).
What to try
- Choose pKa too low and pKa too high, and compare the delivered counts: the first makes particles that cannot escape the endosome, the second makes particles that are cleared in the blood.
- Choose Fatty liver: small fenestrae, or the 180 nm particle, and watch particles bounce off the sieve plates.
- Choose Stealthy PEG: particles stay uncoated by ApoE for longer and fewer are internalised.