MY SIMULATORWHAT-IF UNIVERSE
QUANTUM PHYSICS / NEUTRON SCATTERING

THE POWDER DIFFRACTOMETER EXHIBIT 01

When Planck’s Constant Moves a Neutron Diffraction Peak

A silicon crystal turns a change in quantum wavelength into a shift on a detector arc — until Bragg’s condition has no real solution.

BRAGG REFLECTION
CHAMBER VIEW · drag to pan · schematic, not to scale
INCIDENT NEUTRON BEAM
Si (220) · FIRST ORDER
ILLUSTRATIVE BEAM · λ₀ = 1.500 Å
incident beam diffracted direction detector arc NEUTRON POWDER DIFFRACTION · Si (220)

At the reference value, the neutron wavelength meets the silicon (220) planes at a real Bragg angle. The detector sees a peak at twice that angle.

DE BROGLIE WAVELENGTH SCALED
1.500 Å
λ = h / p · momentum fixed
BRAGG ANGLE PREDICTED
22.99 °
θ from the crystal planes
DETECTOR ANGLE PREDICTED
45.98 °
Scattering angle = 2θ
NEUTRON ENERGY FIXED
36.36 meV
p² / 2mₙ · unchanged

MEASUREMENT / THEORY

Detector arc · angular distribution

THEORY 45.98° · MEASURED 45.9°
synthetic detector events theoryNormalised model counts · illustrative detector resolution

NUMERICAL VALIDATION

Four independent checks

live calculations · % difference
✓
de Broglie closurepλ / h = 1
0.000%
✓
Si (220) spacinga / √8 vs reference
0.000%
✓
Bragg cutoffNumerical root vs closed form
0.000%
✓
Monte Carlo acceptanceSample fraction vs Gaussian theory
0.000%
THE SCIENCEEquations, assumptions & limits+
DE BROGLIE RELATION

λ = h / p

The neutron momentum p is held fixed at its reference value. Scaling h by s therefore scales λ by the same factor: λ(s) = sλ₀.
BRAGG'S LAW · FIRST ORDER

2d sin θ = nλ,   n = 1

For the silicon (220) planes, d = a / √8. A real angle exists only when λ ≤ 2d. The detector scattering angle is 2θ.
NEUTRON ENERGY

E = p² / (2mₙ)

Because p and the textbook neutron mass are fixed, the non-relativistic kinetic energy does not change when h changes. The reference energy is about 36.36 meV.
What is held still? This is a deliberately constrained what-if: the apparatus and silicon plane spacing are frozen at their reference geometry while only h changes in the neutron de Broglie relation. In a fully self-consistent alternate universe, changing h would also alter atomic bonding and the crystal lattice. This exhibit isolates the direct wavelength-to-Bragg-angle consequence; it does not claim to recalculate alternate-universe silicon chemistry.
What the detector model means. The angular histogram is a seeded Monte Carlo of a Gaussian neutron wavelength distribution, filtered by λ ≤ 2d, then blurred by the selected detector resolution. It shows peak position and broadening, not an absolute scattering cross-section, structure factor, or instrument efficiency. The sample is schematic and not to scale.
An independent educational model; not affiliated with NIST, a neutron source, or a diffraction-instrument manufacturer.
Made with 🤖 ChatGPT