◈MY SIMULATOR / QUANTUM OBSERVATORY
INTERACTIVE PHYSICS EXHIBIT SELF-CONTAINED MODEL
WHAT-IF UNIVERSE · ELECTRON DIFFRACTION

When Electron Mass Moves a Diamond Diffraction Pattern

Keep the beam energy and crystal fixed. Change only the electron’s rest mass, then watch its de Broglie wavelength move the Bragg spot — or remove it entirely.

REFERENCE WORLDMeasured electron mass · 1.00×
LIVE CHAMBER

Diamond (311) Bragg reflection

REFLECTION ALLOWED
IDEAL SINGLE-PLANE MODEL
↔ DRAG TO PAN
Incident electrons Bragg reflection Detector arc Schematic, not to scale
NUMERICAL VALIDATIONREFERENCE COMPARISONS
✓
Relativistic wavelength166.891 pm · reference 166.891 pm
0.000%
✓
Diamond (311) spacing107.549 pm · a / √11
0.000%
✓
Reference Bragg angle50.885° · textbook geometry
0.000%
✓
Critical-mass boundaryλ(mcrit) = 2d · closed form
0.000%

Reference constants are fixed; displayed differences compare the calculation with the stated rounded reference values. No fitted parameters are used.

THE SCIENCEEquations, assumptions and limits+

Relativistic electron wavelength

The kinetic energy is fixed at 54 eV (illustrative beam setting). For an electron with rest mass m, its relativistic momentum is

pc = √[K(K + 2mc²)]   and   λ = h / p

Only m is scaled. Planck’s constant, the speed of light, electron charge and kinetic energy remain fixed. At the reference scale, the calculated wavelength is about 166.89 pm.

Diamond lattice and Bragg condition

The diamond cubic lattice parameter is taken as a = 356.7 pm, a rounded room-temperature reference. The selected (311) plane spacing is

d₃₁₁ = a / √(3² + 1² + 1²) = a / √11

For first-order reflection, Bragg’s law is λ = 2d sin θ. A real angle exists only when λ / (2d) ≤ 1. The boundary is therefore λ = 2d; below that mass scale the chosen first-order reflection has no real Bragg angle.

What the exhibit simplifies

  • The crystal is represented by one family of parallel planes and an ideal first-order Bragg condition. The atom motif is schematic, not a full diamond unit cell.
  • Real low-energy electron diffraction can involve surface sensitivity, multiple scattering, structure factors, absorption, thermal motion and instrument geometry. Those effects are not calculated here.
  • The detector scan uses a seeded Monte Carlo angular response with an illustrative 1.2° rms spread. It demonstrates finite measurement resolution; it is not a prediction of absolute diffraction intensity or a material-specific cross-section.
  • The counterfactual changes electron rest mass while holding all other constants and the beam kinetic energy fixed. It is a controlled thought experiment, not a claim that isolated electron mass can be tuned in a laboratory.

Independent educational simulation. Not affiliated with a university, laboratory or instrument manufacturer.

Made with 🤖 ChatGPT