A ONE-CONSTANT THOUGHT EXPERIMENT

The Quantum Gap

How a microscope sees atoms — and what changes when quantum mechanics gets stronger or weaker.

THE KNOBReduced Planck constant0.50×–3.00× its measured value
LIVE CROSS-SECTION/SINGLE-CHANNEL JUNCTION
MODEL GAP4.0 ÅIllustrative · fixed
BARRIER4.50 eVIllustrative · fixed
↔ DRAG TO PAN
i

At the measured value of ħ, the electron wavefunction decays rapidly across the vacuum gap. A small but measurable fraction reaches the sample.

06 / NUMERICAL INTEGRITY

Three independent checks

Reference case · ħ = ħ₀ · model inputs held fixed
CHECK 01
Barrier decay constant
κ = √[2mₑ(U−E)] / ħ
Calculated 1.06236 Å⁻¹Reference 1.06236 Å⁻¹
✓ PASS0.000% difference
CHECK 02
Transfer-matrix transmission
T = 1 / |M₂₂|²
Closed form 1.38447 × 10⁻⁴Matrix form 1.38447 × 10⁻⁴
✓ PASS0.000% difference
CHECK 03
Thick-barrier approximation
T ≈ 16E(U−E)e⁻²κd / U²
Exact 1.38447 × 10⁻⁴WKB 1.38410 × 10⁻⁴
✓ PASS0.027% difference

The checks use the measured reference constant and the stated illustrative junction settings. The WKB comparison is an approximation check, not a second physical model.

THE SCIENCEEquations, assumptions & what the exhibit leaves out+

What changes

The slider sets ħ* = sħ₀, where s runs from 0.50 to 3.00. All other inputs remain fixed. In the classically forbidden vacuum barrier, the wavefunction decays with κ = √[2mₑ(U−E)] / ħ*. Its amplitude decay length is 1/κ. A larger ħ makes the wavefunction penetrate farther.

Exact rectangular-barrier result

For electron energy E below a barrier of height U and width d, T = [1 + U² sinh²(κd) / (4E(U−E))]⁻¹. This is the exact one-dimensional transmission probability for a rectangular barrier with equal potentials on both sides.

Current estimate

In the small-bias, single-channel Landauer limit, I = (2e²/h*)VT, with h* = 2πħ*. The conductance quantum therefore changes as ħ changes. This is an idealised one-mode estimate, not a prediction for the total current of a particular commercial microscope.

Assumptions & limitations

The barrier is flat and one-dimensional; electrons are coherent and non-interacting; the electrodes have matching free-electron leads; and the voltage is small enough for a linear-response estimate. Real tips have many channels, atomic structure, image-potential corrections, inelastic processes and a spatially varying barrier. The model does not calculate an actual image or a material-specific work function.

Reference versus illustration. ħ₀, electron mass and elementary charge are textbook constants. The 4.50 eV barrier, 0.20 eV incident energy, 4.0 Å gap, 10 mV bias and 10 nA feedback limit are illustrative model settings. The wavefunction and atom lattice are visual explanations, not to-scale renderings. This educational exhibit is independent and is not affiliated with any microscope manufacturer or research institution.