Observe. Compare. Question.
Trajectory & probability atlas
The field notebook.
Capture instrument settings, actual atom counts, and measured probabilities for comparison. Records stay in this browser session and export as CSV.
| # | Mode | G₁ / T m⁻¹ | θ₁ / ° | θ₂ / ° | Detected / Fired | Measured P(+) | Theory P(+) | d′ |
|---|---|---|---|---|---|---|---|---|
| No readings yet — fire atoms and record a measurement. | ||||||||
Earn your quantum credentials.
Four calculation problems, two theory checks, and four live experiments verified against the apparatus — not just a button press.
What a spin really means.
Read before experimenting — or use the apparatus first and return with questions.
01. A beam that should not split — but does
In 1922 Otto Stern and Walther Gerlach sent neutral silver atoms through an inhomogeneous magnetic field. Silver atoms contain one unpaired electron, giving an effective magnetic moment. A classical picture of arbitrary moment orientations suggested a continuous smear on a detector. Instead, two discrete beams appeared: quantum spin projection along the selected axis takes only two outcomes. SPINTRACE lets you construct the modern idealised spin-one-half version of that demonstration using a simulated source, analyser, optional second analyser, spatial selector and detector.
02. Operating your instrument
Choose one of five modes along the top, set the gradient and orientation using labelled controls, then choose Fire atoms. The three-dimensional trajectories are generated from exact flight equations and random draws from the relevant quantum probabilities. Drag the view to orbit; shift-drag to pan, scroll to zoom, or use the reset and top-view buttons. Drag the rotation grip on the first magnet or use its slider and arrow keys. Pause and vary playback speed to examine the paths. The physical displacement in the viewport is exaggerated 350-fold to make micrometre and millimetre deflections visible; values in the instruments and graphs remain in SI-derived units.
03. Forces and measured spin
An atom in a field gradient experiences the approximate transverse force F = s μB G, with spin sign s = ±1, Bohr magneton μB = 9.274 × 10⁻²⁴ J/T and magnetic gradient G in T/m. The silver-atom mass is 1.7908 × 10⁻²⁵ kg. Thus a = s μBG/m. Inside a magnet of length L, a beam moving at axial speed v spends t = L/v in the gradient. Its transverse displacement by a downstream detector at drift distance D is y = a(L/v)[D/v + L/(2v)]. The two ideal peak centres are separated by twice this magnitude. With a finite source spot and transverse velocity spread, their distribution broadens rather than making every atom land at the centre.
04. Five connected investigations
Quantum Splitter: Start with an unpolarised beam and predict equal average populations, then increase magnetic gradient and compare spot separation. Rotating Axis: Prepare spin in the + direction at an angle you set, then turn the analyser. Check the probability law P(+) = cos²[(θsource − θ₁)/2]. A 90° offset produces half in each branch; a 180° offset reverses the outcome. Sequential Analysers: A physical aperture at the intermediate plane transmits one branch, within a finite selectable slit width. The second apparatus measures along a new axis. If the first outcome has sign s, the ideal downstream probability is [1 + s cos(θ₁ − θ₂)]/2. A tiny amount of opposite-branch contamination may pass through a wide physical aperture, so actual counts are calculated atom by atom rather than forced to match the ideal formula.
Beam Resolution: Vary gradient, speed, source width and angular divergence. Predict the ideal peak distance Δ = 2|y| and the RMS beam width σ = √[σ₀² + (σv⊥T)²], where T is the total source-to-screen flight time. The readout d′ = Δ/σ measures nominal separation, not probability. Quantum Counting: Collect batches and observe binomial shot noise; the fraction of + outcomes fluctuates around a fixed Born probability and does not equal it exactly for finite N.
05. Suggested experiments and predictions
First keep the beam speed fixed and double the magnetic gradient. Predict twice the peak separation, then compare the histogram and graph. Next double speed; the ideal split decreases approximately with the inverse square of velocity because both magnet exposure and downstream drift times shorten. In Rotating Axis mode, compare 0°, 90° and 180° settings for a prepared + state and collect at least 1,000 atoms. In Sequential mode, choose the + aperture, align two axes, then rotate only the second by 90° and 180°. Watch the downstream count fraction. Finally, broaden the source beam in Resolution mode until the detector peaks overlap, even though every simulated atom still has a definite ± quantum result.
06. What the graph and detector mean
The detector chart displays actual accepted impact positions, projected onto the first analyser's transverse measurement axis. For a single analyser, the overlay is a two-Gaussian approximation calculated using the average beam speed; shot-to-shot longitudinal speed variation can slightly broaden the real sampled spectrum. The second chart changes with your experiment: it may show spin-centre trajectories, Born probabilities versus axis angle, ideal spatial resolution versus gradient, or observed cumulative frequencies. Hover or tap a graph to inspect values. Save measurements to the notebook and export them as CSV for your own analysis.
07. Applications, assumptions and limitations
The Stern–Gerlach principle motivated spin-state preparation, quantum measurement theory, magnetic atomic-beam methods and the later development of atom-based spectroscopy and quantum information. This model assumes an ideal effective spin-½ silver beam, one-dimensional constant magnetic gradient within each magnet, negligible field outside, classical transverse centre-of-mass motion between projective spin measurements, and no scattering or inter-atomic interactions. The spin randomisation models a measurement of an incoherent ensemble, not a full coherent wavepacket propagator. It does not simulate magnetic fringe fields, quantum wavepacket interference, adiabatic spin dynamics, realistic source ovens, collisions or detector inefficiency. The ideal analyser is not a claim that a tabletop apparatus of the pictured dimensions is available.
08. Glossary and further questions
Quantisation — a measured projection admits discrete eigenvalues. Born rule — the squared quantum amplitude gives outcome probabilities. Post-selection — accepting events consistent with a chosen result. Magnetic gradient — the spatial rate of change of field strength. Shot noise — counting uncertainty associated with finite independent trials. Resolution — separation of two features compared with their width. Incoherent mixture — a probability distribution over states without observable relative quantum phase. Questions to explore: Why does a wide slit degrade spin purity? Does a 90° second measurement restore the originally discarded outcome? What features would a coherent Stern–Gerlach interferometer require that this model deliberately omits?