SCANNING TUNNELLING MICROSCOPE

How Electron Mass Changes a Tunnelling Current

TUNNELLING
WKB MODEL · LIVEDRAG TO PAN
MEASURING EXPERIMENT

Scan one atomic repeat

Synthetic tip-current samples compared with the WKB prediction

⌁Run the scan to compare measured points with theory
64 samples · one illustrative unit cell · synthetic data, not laboratory measurements
MODEL VALIDATION

Numerical checks

Independent calculations compared with the displayed model

LIVE CHECKS
01

Barrier integral

Simpson integration of κ across the rectangular barrier versus the closed-form WKB exponent.

0.000%relative difference
02

Current scaling

Displayed current ratio versus the independent low-bias relation (V / V₀)(T / T₀).

0.000%relative difference
03

Scan convergence

128-point and 2,048-point midpoint estimates of the mean current over one unit cell.

0.000%relative difference
04

Textbook electron mass

Recomputed baseline decay constant against κ = 10.868 nm⁻¹ for the stated reference barrier.

0.000%relative difference

Checks validate the equations and numerical implementation, not the simplifications of the physical model. Rounded textbook reference shown.

MODEL NOTESThe scienceEquations, assumptions and what the exhibit leaves out
WKB transmission through a rectangular barrier

T ≈ exp(−2κd),   κ = √(2mₑΦ) / ℏ

d is the local vacuum gap; Φ is the barrier energy above the incident electron energy.

What changes

The counterfactual slider changes only the electron mass, mₑ. The electron charge, reduced Planck constant, barrier energy, geometry and low-bias reference remain fixed. The decay constant κ grows with the square root of mass, so the probability falls exponentially with gap width.

What stays stable

The tip and sample remain conductors separated by vacuum. The gap does not close when the current becomes small. There is no sharp physical on/off threshold in this model; the “signal fades” preset crosses an explicitly illustrative display floor.

Simplifications

This is a one-dimensional, zero-temperature, rectangular-barrier WKB model. Current is proportional to bias in the low-bias approximation and is normalized to an illustrative 1 nA at the reference setting. Real STM current also depends on tip and sample density of states, atomic orbitals, barrier shape, image forces, temperature and instrument feedback.

Reference labels

Electron rest mass and ℏ are textbook constants. The 4.50 eV barrier, 0.60 nm reference gap, 0.32 nm lattice repeat, 0.018 nm corrugation and 1 nA current scale are illustrative exhibit settings, not measurements of a particular instrument or material.

An educational physics model; not affiliated with a microscope manufacturer, laboratory or research institution.

Made with 🤖 ChatGPT