Textbook model — For a circular tank, A = πR² and a = πd²/4. Head h is measured above the outlet.
Q = Cda√(2gh)
A dh/dt = Qin − Q − Qspill
t(h₀→h₁) = 2A(√h₀−√h₁)/(Cda√(2g))
heq = (Qin/(Cda))²/(2g)
Midpoint integration uses a fixed 1/120 s step (illustrative numerical setting). Outflow is limited by available water; volume above the illustrative 2 m rim is assigned to overflow. The outlet is idealised as a point at the tank floor. The discharge coefficient represents contraction and losses; water is incompressible and the tank is vented. No sloshing, viscosity model, pressure piping, surface tension or structural loads are simulated. Jet path uses ideal ballistic speed; tank drawing and animation are scaled for legibility.
Independent educational exhibit; not affiliated with any equipment manufacturer. Not a design or safety-sizing tool.