The Oil Drop and the Quantum of Charge
Watch a speck of oil reveal a fundamental constant.
Numerical verification
MODEL CHECKSFrom the original notebook
HISTORICAL / TABLE IVDrop no. 6 · plate gap 16.00 mm · observation path 10.21 mm · oil density 919.9 kg/m³ · radius 2.76 µm · mean voltage 5,085 V · temperature 22.82 °C · pressure 75.62 cm Hg.
Recorded mean fall: 11.880 s. Recorded rise at 24 charges: 22.366, 22.390 and 22.368 s. The present model uses modern charge and an approximate slip law, not a replay of those timings.
The science — equations, uncertainty and sources
Drift and diffusion
Effective weight W = (4π/3)r³(ρoil − ρair)g. Drag coefficient β = 6πηr/Cc, with Cc = 1 + b/(pr), b = 0.0082 Pa·m (illustrative teaching approximation). Upward terminal drift u = (neV/d − W)/β. Field-off fall speed f = W/β. D = kBT/β.
At fixed 0.02 s intervals the position follows Δy = uΔt + √(2DΔt)Z, with independent standard normal Z. The microscope gates are interpolated on crossing. Timing readout adds an illustrative 0.03 s Gaussian error and 0.002 s resolution; each pair shares an illustrative 0.05% voltage calibration error. An analysis toggle can deliberately omit slip. Air density is estimated by the ideal gas law, and viscosity by Sutherland scaling around the historical reference.
Inference
From f = L/tfall, let A = 9ηf/[2(ρoil − ρair)g]. Then r = (√((b/p)²+4A) − b/p)/2. With rise speed v = L/trise, ê = β(r)(f+v)d/(nVread). The supplied n makes this a guided constant measurement; historical quantisation was inferred from repeated charge changes. Averages are unweighted across successful trials; displayed ± is sample standard error, not total uncertainty.
Historical comparison
Millikan reported (4.774 ± 0.009) ×10⁻¹⁰ statC, or (1.59243 ± 0.00300) ×10⁻¹⁹ C. His uncertainty was an estimated limit, not a modern confidence interval. The modern SI value is exactly 1.602176634 ×10⁻¹⁹ C. Reference: R. A. Millikan, Physical Review 2, 109–143 (1913), DOI 10.1103/PhysRev.2.109, Table IV and p. 140. SI reference: BIPM SI Brochure, ninth edition.
Scaled diagram, not a literal optical reconstruction. The drop is magnified; walls, evaporation, convection, charge jumps during a pair and optical diffraction are omitted. The drop is repositioned between phases. No real high voltage is involved. Independent educational exhibit; not affiliated with any historical institution.