Inferred charge per electron
Synthetic repeat-run values; error bars are one standard error, not Millikan’s historical uncertainty.
The science: equations, noise and limits
Historical apparatus. An atomizer introduced oil droplets between horizontal metal plates. Charged droplets were illuminated and watched through a microscope. A controllable electric field could make a selected drop rise. The 386 V and 7.67 mm settings are from a modern teaching-lab transcription, not claimed as Millikan’s exact 1913 settings.
Force balance. With field off, terminal fall speed \(v_f\) obeys \(6πηrv_f=(4/3)πr^3(ρ_o−ρ_a)g\), so \(r=√[9ηv_f/(2(ρ_o−ρ_a)g)]\). With field \(E=V/d\) on and upward speed \(v_r\), \(qE=6πηr(v_f+v_r)\), hence \(q=6πηr(v_f+v_r)d/V\). A Cunningham slip correction is included for micron-scale drops.
Noise model. Stopwatch errors are independent Gaussian timing perturbations. Brownian motion adds Gaussian displacement with standard deviation \(√(2Dt)\), where \(D=k_BT/(6πηr)\) is the Stokes–Einstein diffusion coefficient. This is a one-dimensional displacement model, not a full stochastic fluid solver. Simulated charges are integer multiples of the modern elementary charge; the analysis is not told that integer.
Checks and historical error bar. The page independently recomputes a force-balance mean, scans candidate values against the integer lattice, and compares with the modern exact SI value \(1.602176634×10^{-19}\) C. Millikan reported \(1.592×10^{-19}\) C in 1913 with a stated uncertainty of 0.2%; the modern value is about 0.64% higher. The 0.2% bar is his reported historical uncertainty, not a reanalysis of every notebook entry. Live error bars are simulated run-specific standard errors.
Simplifications. The schematic is not to scale. The model assumes spherical drops, constant viscosity and density, laminar Stokes drag, uniform field, constant radius during timing, and independent noise. It omits evaporation, convection, charge leakage during a timing, plate-edge fields, and correlated observations. Weak-field conditions can fail; the interface reports failure instead of inventing a result.
This educational reconstruction is not affiliated with Millikan’s estate, the University of Chicago, or any historical instrument collection.