Why the drop reveals e
With the field off, gravity minus buoyancy is balanced by viscous drag. With the field on, the electric force adds to the upward force. The drop’s terminal speeds therefore reveal its charge without weighing it.
vf = 2 Δρ g r² / 9 η · C
C = 1 + b / (p r)
q = 6 π η r / C E · (vf + vr)
qi = ni e, ni ∈ ℕ
Noise model
Brownian displacement is a Wiener process with diffusion coefficient D = kBT C/(6πηr). Its first-passage timing spread is approximated by σt,B = √(2Dt)/v. Independent Gaussian chronoscope scatter is added, then readings are quantised to 0.002 s. Repeated timings are averaged. The original instrument was calibrated, with reported timing corrections of up to 0.2%.
What is simplified
The drop is spherical, the air is isothermal, the field is uniform, terminal motion is assumed, and the empirical first-order slip correction is applied. The chamber animation is enlarged and the 1.00 mm timing path is illustrative. The historical chamber dimensions, voltage, oil density and chronoscope resolution are documented values; the new readings are simulated, not Millikan’s raw notebook data.
Independent educational reconstruction. Not affiliated with the University of Chicago, the American Physical Society or the Millikan family.