Actual x displacement
Coriolis vibratory
gyroscope observatory.
Build a precision rate sensor. Excite resonance, rotate the stage, separate spurious coupling, and extract the physics hidden inside every micrometre.
EXPERIMENTS
Resonance chamber
Drive and response
Actual y displacement
Rotating-frame effective energy
Normalized integration residual
Signals, not illustrations.
Computed from the equations of motion. Hover to inspect; click the transfer curve to retune the drive.
Measured observations.
Capture real simulation states, compare two runs, and export raw measurements for your own analysis.
| Run | Mode | Time | Ω (°/s) | x (mm) | y (mm) | E (µJ) |
|---|---|---|---|---|---|---|
| No observations recorded yet. | ||||||
Prove the physics.
12 self-checking challenges across six labs. Solutions respond to the current apparatus parameters.
Understand the mechanism.
01 A gyroscope with no spinning wheel
A vibratory gyroscope measures angular velocity using a resonating mass rather than a rapidly spinning rotor. A mechanical oscillator is deliberately driven along one direction while its support frame rotates. In the rotating frame, a moving mass experiences a transverse Coriolis acceleration. The resulting tiny motion along a perpendicular sense direction becomes an angular-rate signal.
SENSEFORGE represents a single in-plane proof mass supported by compliant flexures. The visible geometry expands physical displacements by 410 times so that millimetre-scale screen movement can represent real sub-millimetre dynamics. The equations, graphs and numerical readouts retain true SI values; visual exaggeration changes no measurements.
02 The equations behind the motion
Let x and y be displacements in metres in the frame fixed to the rotating stage, with stage angular velocity Ω in rad/s about the perpendicular z axis. Define ωₓ = 2πfₓ and ωᵧ = 2πfᵧ. The oscillator has damping γₓ = ωₓ/Qₓ and γᵧ = ωᵧ/Qᵧ, and a symmetric dimensionless cross-spring coefficient κ. Force per unit mass along x is a₀ cos(ωdt), with a₀ = F₀/m.
The velocity cross-terms are Coriolis acceleration. The terms −Ω²x and −Ω²y are centrifugal corrections for constant rotation. A nonzero κ represents reciprocal elastic coupling, not a second rate signal. Each time step uses fourth-order Runge–Kutta integration with a frame-independent simulation timestep of at most 1/2400 second. The complex-valued frequency sweep uses the exact linear steady-state phasor equations at each drive frequency.
03 Operating the observatory
Choose any numbered experimental mode across the top. Use the right-hand controls to adjust measured frequency, force, mass, damping, rate and imperfection. Every change to a physical parameter begins a fresh controlled run so the energy ledger remains interpretable. Play or pause the integrator, reset initial conditions, or increase simulation speed. Drag empty 3D space to orbit; Shift-drag to pan; scroll or pinch to zoom. Select a drive frequency directly from the lower frequency-response graph.
The left oscilloscope plots actual x-probe and y-mass displacement versus simulation time. The right chart displays steady-state response, ringdown energy, or the free orbit, depending on the experiment. Record observations in the notebook and export CSV files. Complete two parameter-aware challenges in each laboratory; use hints when necessary and review the explanation after answering.
04 Six investigations
Resonance chamber. First set the rotation rate to zero and scan the drive frequency across fₓ. Hypothesize where the x amplitude peaks. Raise Qₓ: less damping produces a sharper resonance and a longer transient settling time.
Coriolis rate table. Restore a moderate rotation, drive near resonance, and inspect the cross-axis response. Reverse the rate while retaining the same settings. Predict why the y-phase changes even when the amplitude magnitude stays nearly the same. Compare signals at 1°/s and 6°/s: the response is approximately linear only for small rates and weak coupling.
Mode-matching foundry. Bring fᵧ toward fₓ, retaining a nonzero rotation. Observe how the sense-axis response grows near a shared resonance. Now detune it by half a hertz.
Quadrature clinic. Add cross stiffness κ while keeping the stage stopped, then introduce nonzero rotation. A stiffness error feeds the x displacement into y; Coriolis force instead depends on x velocity. These sources are about ninety degrees apart in a single-frequency idealization. Use the analytical frequency response to understand how both contaminate the sensor output.
Ringdown observatory. Begin from a displaced mass with the drive disabled. Observe the diminishing oscillations and energy. For one weakly damped uncoupled mode, the displacement envelope decays with time constant 2Q/ω, while energy decays with Q/ω. Multiple modes with different quality factors generally do not produce one perfect exponential.
Free-precession gallery. With matched axes and very light damping, release the mass on a turning stage. In an inertial frame, an almost fixed oscillation direction looks rotating to observers standing on the table. Predict the sense of precession for positive and negative Ω, then test how detuning spoils the simple picture.
05 Scientific measurements and energy
The measured kinetic plus effective rotating-frame potential energy per mass is E = ½(vₓ²+vᵧ²) + ½[(ωₓ²−Ω²)x²+(ωᵧ²−Ω²)y²+2κωₓωᵧxy]. For fixed parameters it obeys dE/dt = a₀ cos(ωdt)vₓ − γₓvₓ² − γᵧvᵧ². Coriolis acceleration does no work because it is perpendicular to the velocity. SENSEFORGE integrates drive work and dissipated work with the same RK4 stages as the motion, reporting a normalized energy-accounting residual.
The cyan probe samples a simplified smooth clamped-guided flexure displacement shape, s(u) = 3u² − 2u³. It reports x-probe = s(u)x; this is an idealized kinematic pickup, not a finite-element beam solution. Compare probe locations to see how position changes sensor gain without altering underlying mass dynamics.
06 Where the physics matters
Vibratory rate gyroscopes underpin inertial navigation, robotic stabilization, smart-device screen orientation, camera gimbals and vehicle control. Practical instruments use capacitive or optical displacement readout, feedback loops, temperature compensation and quadrature suppression.
07 Assumptions, glossary and further questions
Assumptions: two linear displacement coordinates, a rigid stage rotating at constant Ω during each run, constant lumped mass, linear viscous damping, conservative symmetric cross stiffness, ideal harmonic forcing and no feedback circuit. There is no electronic noise, quantization, thermal drift, acceleration cross-sensitivity, nonlinear spring law or real MEMS geometry model. This is a physically derived teaching model, not a calibrated commercial gyroscope. Rate changes reset the run; angular acceleration and the Euler force are therefore excluded.
Glossary: Coriolis acceleration—transverse inertial acceleration in a moving rotating frame; proof mass—oscillating inertial element; Q factor—ratio governing resonant linewidth and energy loss; mode matching—aligning two resonant frequencies; quadrature—an unwanted displacement-coupled component; phasor—complex representation of steady harmonic oscillation; ringdown—free decay after excitation stops.
Explore further: How would electronic feedback increase bandwidth? How does sensor calibration change when the sense mode is detuned? Which noise sources determine the smallest measurable Ω? What new terms arise if stage angular velocity changes continuously? How could a differential two-mass design suppress linear acceleration pickup?