Pressure and Flow Inside a Venturi Meter
Follow the water through a narrowing pipe. Read the pressure taps, then infer the flow.
Pressure-tap experiment
Sample the noisy differential pressure and calculate flow from the ideal tap equation.
| Time (s) | Δp (kPa) | Inferred (L/s) | Model (L/s) | Error |
|---|
Illustrative Gaussian instrument noise; invalid negative readings are retained, not silently corrected. Samples are not valid if the single-phase model fails.
Independent numerical checks
Textbook relations compared with numerical calculations using the selected model inputs.
Passing arithmetic checks do not validate a cavitating flow. Percent differences are relative to the closed-form values.
The science Equations, assumptions and limitations
Conservation and pressure
Textbook relations: A = πD²/4, β = d/D, Q = Aₜvₜ and v₁ = β²vₜ. The horizontal, inviscid tap relation is Δp = ½ρ(vₜ² − v₁²). Thus Q = Aₜ√[2Δp / (ρ(1 − β⁴))].
The illustrative lumped transient model is L dvₜ/dt = ΔP/ρ − Kvₜ²/2. Here ΔP is the permanent pressure drop between equal-diameter ends, not the tap difference. Its equilibrium is v∞ = √(2ΔP/(ρK)). A fixed 1/240 s model step advances velocity with a midpoint method. Absolute inlet pressure is p₁ = p_out + ΔP; the quasi-steady throat estimate is pₜ = p₁ − Δp. This neglects local transient acceleration and distributed loss between taps.
Textbook/reference parameters: water density 998 kg/m³ (approximate at 20 °C); water vapour pressure 2.34 kPa absolute (approximate at 20 °C). Once pₜ reaches that pressure, the liquid-only equations cease to describe the real flow. Negative calculated absolute pressures are flagged as nonphysical extrapolations. The schematic does not solve turbulence, bubble formation, compressibility, pressure recovery or wall boundary layers.
Verification: midpoint integration of the uniform throat velocity over annular area, midpoint quadrature of ρv dv through the contraction, and independent Euler relaxation to equilibrium. Noise is illustrative independent normal pressure error with the chosen standard deviation; no claim of calibrated instrument accuracy is made. This educational simulation is not affiliated with an instrument manufacturer.