Model and fit
T = 2π√(L/g) ⇒ T² = (4π²/g)L
Plot measured T² against measured L. The least-squares slope m gives
g = 4π²/m. The intercept is fitted rather than forced to zero, so a timing offset can be noticed.
σg ≈ (4π²/m²) σm
Assumptions
- The bob is treated as a point mass; the string is light and inextensible.
- The pivot is fixed and the motion is planar; the release angle is 5°.
- The small-angle equation is used. A small finite-amplitude correction is included in the simulated motion.
- Reference value is g = 9.81 m/s²; local variations with latitude and altitude are ignored.
Instrument model
The ruler rounds to 1 mm. The stopwatch rounds to 0.01 s and adds seeded Gaussian reaction-time noise with σ = 0.12 s over ten oscillations. The same seed reproduces the same dataset.
Toggle effects
Pivot friction and air drag are represented by small calibrated period biases, not a full fluid/hinge simulation. Parallax adds a 4 mm length-reading bias. Heat loss is not relevant to this pendulum experiment.
Honest simplifications
The 3D apparatus is a scale teaching model, not a CAD-certified instrument. The pendulum animation is accelerated for usability; data are generated by the pure physics module, not by timing rendered frames. The fit uncertainty is the standard error from regression residuals and does not include every systematic uncertainty.