At terminal speed: gravity minus buoyancy is balanced by viscous drag. With the field on, electric force also acts on the drop.
vfall = 2 a² Δρ g / 9 η · Cc
q = 6 π η a / Cc · (vfall + vrise) / E
Slip correction: Cc = 1 + 0.874 λ/a, Millikan’s first-order empirical correction. The radius is recovered from the fall speed.
Real timing noise: Brownian motion makes a drifted drop’s first-passage time inverse-Gaussian, with variance 2DL/v³. D = kBT/ζ. The model also quantises times to the chronoscope’s readout and applies a small residual calibration error inside Millikan’s reported 0–0.2% envelope.
1913 reference constants: clock-oil density 919.9 kg/m³; air viscosity 1.824 × 10⁻⁵ Pa·s at 22.82 °C; original supply readings 5,088.8 → 5,081.2 V. These are historical values; the live repeat count and generated timings are illustrative.
Simplifications: spherical rigid drops, laminar Stokes drag with Millikan’s first-order slip term, constant temperature, no convection, and a uniform field. The simulation generates repeat data from the modern exact charge; it does not claim to recreate Millikan’s entire 58-drop notebook.
An independent educational reconstruction; not affiliated with Caltech, the American Physical Society or the University of Chicago.