The balance inside a drop
At terminal speed, buoyancy-corrected weight W = (4/3)πr³(ρoil − ρair)g is resisted by slip-corrected viscous drag γv, with γ = 6πηr/C and C = 1 + b/(pr). An upward electric force on a negatively charged droplet is qV/d.
vfall = W/γ · field off
vrise = (qV/d − W)/γ · field on
q = γ(vfall + vrise)d/V · if it rises
We infer radius by numerically inverting the first equation, not by using the hidden radius. From charges measured on multiple drops we fit qi ≈ nie, with integer ni. An illustrative, disclosed search interval of 1.25–1.95 × 10−19 C avoids ambiguous submultiples in this short exhibit; it is not a wholly assumption-free discovery.
Noise you can actually model
The simulator uses the overdamped Langevin process Δz = vΔt + √(2DΔt)N(0,1), D = kBT/γ, at fixed 0.01 s steps during timed trials. The real Brownian noise model is used at 1× intensity. Extra endpoints have Gaussian optical localisation noise of 1.5 µm, and the clock has your selected Gaussian timing jitter plus 0.002 s quantisation. Uncertainties are propagated numerically from timing, Brownian wandering and localisation.
Oil density 919.9 kg/m³, g = 9.80665 m/s², air density 1.2 kg/m³, η = 1.828 × 10−5 Pa·s, pressure 101,325 Pa and b = 8.20 × 10−3 Pa·m are fixed model values unless a control says otherwise. Temperature changes Brownian diffusion, not viscosity. Drag is always terminal; evaporation, convection, charge changes during a crossing and detailed telescope optics are omitted. Droplets are vastly magnified in the illustration.
What is original, and what is not?
Millikan's 1913 Physical Review apparatus had 16 mm spaced plates, a 5,300 V battery, a telescope, a chronoscope resolving 0.002 s and clock oil density 0.9199 g/cm³. His reported elementary charge was (4.774 ± 0.009) × 10−10 electrostatic units (approximately 1.5924 ± 0.0030 × 10−19 C). The original reported error bar is reproduced, not relabelled as a modern standard deviation. The current SI charge is exactly 1.602176634 × 10−19 C.
The 1913 value is about 0.61% low, more than the quoted error range; historical reassessment attributes an important systematic discrepancy to the air-viscosity value. This exhibit does not present simulated drops as archival observations. It is an independent educational reconstruction, not affiliated with the original researchers or any institution.