THE SCIENCE COLLECTION / EXPERIMENTS
INTERACTIVE EXHIBIT NO. 07
RECONSTRUCTED EXPERIMENT CHICAGO · 1913

The Oil Drop /
Weighing a Single Electron

Can a speck of oil reveal nature's smallest unit of charge? Switch on the field, time a droplet and build your own noisy evidence.

ORIGINAL STUDY58published drops
HISTORICAL RESULT1.5924× 10−19 C · 1913
01 THE APPARATUS · RECONSTRUCTED CUTAWAY
FIELD ON · OBSERVING
ELECTRIC FIELD SIMULATED
56.3kV/m
DROP POSITION LIVE
+0.000mm
TERMINAL FALL THEORY
72.5µm/s
BROWNIAN DIFFUSION EINSTEIN
22.3µm²/s
03 THE EVIDENCE

Charge comes in steps.

0 DROPS

Every point is a measured charge, not a pre-drawn answer. Dashed marks show the integer steps of the fitted charge quantum.

MEASURED q ± 1σ FITTED MULTIPLES
DROPFALL (s)RISE (s)q (×10−19 C)RESULT
Your notebook is empty. Record a droplet to begin.
04 THE VERDICT

Then and now.

× 10−19 COULOMBS
1913 · PUBLISHED1.5924 ± 0.0030
2019 SI · EXACT1.60218
YOUR FIT · STATISTICAL—

The 1913 error bar is Millikan's reported ±0.009 × 10−10 statC, converted to SI. It did not include the later-discovered air-viscosity bias. Collect three or more valid drops to reveal your fit.

06 THE SCIENCE Equations · measurement noise · historical caveatsEXPLORE THE METHOD ⌄

The balance inside a drop

At terminal speed, buoyancy-corrected weight W = (4/3)πr³(ρoil − ρair)g is resisted by slip-corrected viscous drag γv, with γ = 6πηr/C and C = 1 + b/(pr). An upward electric force on a negatively charged droplet is qV/d.

vfall = W/γ · field off
vrise = (qV/d − W)/γ · field on
q = γ(vfall + vrise)d/V · if it rises

We infer radius by numerically inverting the first equation, not by using the hidden radius. From charges measured on multiple drops we fit qi ≈ nie, with integer ni. An illustrative, disclosed search interval of 1.25–1.95 × 10−19 C avoids ambiguous submultiples in this short exhibit; it is not a wholly assumption-free discovery.

Noise you can actually model

The simulator uses the overdamped Langevin process Δz = vΔt + √(2DΔt)N(0,1), D = kBT/γ, at fixed 0.01 s steps during timed trials. The real Brownian noise model is used at 1× intensity. Extra endpoints have Gaussian optical localisation noise of 1.5 µm, and the clock has your selected Gaussian timing jitter plus 0.002 s quantisation. Uncertainties are propagated numerically from timing, Brownian wandering and localisation.

Oil density 919.9 kg/m³, g = 9.80665 m/s², air density 1.2 kg/m³, η = 1.828 × 10−5 Pa·s, pressure 101,325 Pa and b = 8.20 × 10−3 Pa·m are fixed model values unless a control says otherwise. Temperature changes Brownian diffusion, not viscosity. Drag is always terminal; evaporation, convection, charge changes during a crossing and detailed telescope optics are omitted. Droplets are vastly magnified in the illustration.

What is original, and what is not?

Millikan's 1913 Physical Review apparatus had 16 mm spaced plates, a 5,300 V battery, a telescope, a chronoscope resolving 0.002 s and clock oil density 0.9199 g/cm³. His reported elementary charge was (4.774 ± 0.009) × 10−10 electrostatic units (approximately 1.5924 ± 0.0030 × 10−19 C). The original reported error bar is reproduced, not relabelled as a modern standard deviation. The current SI charge is exactly 1.602176634 × 10−19 C.

The 1913 value is about 0.61% low, more than the quoted error range; historical reassessment attributes an important systematic discrepancy to the air-viscosity value. This exhibit does not present simulated drops as archival observations. It is an independent educational reconstruction, not affiliated with the original researchers or any institution.

Made with 🤖 ChatGPT · Three.js