HISTORICAL EXPERIMENT · PHYSICS
The oil-drop experiment
1913 sourceillustrative repeatscaled motion
THE APPARATUS

One tiny drop. One fundamental charge.

RECONSTRUCTED INSTRUMENT
FIELD + MOTION
READY · FIELD OFF
ELECTRIC FIELD ILLUSTRATIVE
317.8 kV/m
Voltage ÷ plate gap
FALL SPEED MODEL
0.86 mm/s
Gravity balanced by air drag
INFERRED DROP RADIUS MODEL
2.76 µm
From the mean field-off fall time
BROWNIAN DIFFUSION MODEL
0.0043 µm²/s
Einstein–Stokes diffusion coefficient
OBSERVATION LOG

Measured timings

0 readings
#Fall t₀ sRise tF sCharge q ×10⁻¹⁹ C
No readings yet. Take a timing to begin.
† marks timings transcribed from the 1913 paper; unmarked rows are illustrative synthetic readings. The hidden charge state is not shown.
YOUR MEASUREMENT VS THEORY

Elementary charge

AWAITING DATA
YOUR FIT ILLUSTRATIVE REPEAT
—
Collect at least 4 readings
MODERN SI VALUE EXACT
1.602176634
× 10⁻¹⁹ C · NIST 2022 CODATA
Historical result and original uncertainty
Millikan 1913 ± estimated limit Modern exact value Your fit
1913: 1.5924 ± 0.0030 · modern: 1.6022 · ×10⁻¹⁹ C
INDEPENDENT NUMERICAL CHECKSdifference from paired estimate
Closed-form drag balance—Collect readings
Median charge spacing—Collect readings
Bootstrap cross-check—Collect readings
1913 published value−0.61%Historical vs modern
THE SCIENCEEquations, noise model and historical simplifications +

Terminal motion

v₀ = 2g a²(ρₒ − ρₐ) C / (9η)

At terminal speed, buoyant weight equals viscous drag. The first-order slip factor is C = 1 + b/(pa), using Millikan’s empirical correction with pressure p in cm Hg and radius a in cm.

Charge from two timings

q = mg / E · (1 + t₀ / tF)

Here t₀ is the field-off fall time and tF is the field-on rise time over the same cross-hair distance. The charge states cluster near integer multiples of e.

Physical measurement noise

D = kBT / β   and   σₓ² = 2Dt

Brownian displacement is a diffusion process. The simulated crossing time follows the inverse-Gaussian first-passage distribution for drift plus diffusion, then receives independent Gaussian chronoscope scatter. The visual drop uses fixed-step overdamped Langevin motion.

What is simplified

The exhibit models one spherical drop, laminar Stokes drag, a uniform electric field, fixed oil density, and a first-order empirical slip correction. It omits convection, evaporation, field distortion, charge-polarity reversals and the full 58-drop pressure-series reduction. Fresh runs are illustrative synthetic repeats; Table IV replay uses the printed historical timings.

Independent educational reconstruction. Not affiliated with Robert A. Millikan’s estate, the University of Chicago, the American Physical Society, or NIST.

Made with 🤖 ChatGPT