Terminal fall: the effective weight is balanced by corrected Stokes drag.
vf = [2a²(ρoil − ρair)g / 9η] · C
Slip correction: C = 1 + Aλ/a. The model uses A = 0.874, the empirical coefficient reported by Millikan, and an illustrative atmospheric mean free path λ = 66 nm.
Historical inputs: oil density 919.9 kg/m³ and air viscosity 1.8240 × 10⁻⁵ Pa·s at 23 °C; the original apparatus used a 5,300 V supply and a 16.00 mm plate gap. The 66 nm mean free path is an illustrative model input, not a quoted Millikan measurement.
Electric rise: for charge magnitude q = ne, qE = 6πηa(vf + vr)/C, so each charge state gives an estimate of q.
ê = Σ(nq) / Σ(n²) and E = V/d
Real noise model: Brownian displacement is Gaussian with variance 2Dt, where D = kBT C/(6πηa). Each endpoint also has optical reading uncertainty; each timed track has Gaussian chronoscope jitter. A persistent voltmeter offset is modelled separately as systematic error.
Model simplifications: spherical drops, constant terminal drift, uniform field, constant oil density, no air convection, and a first-order slip correction. The animation uses fixed-step integration with exact exponential drag relaxation; the measurement calculation uses the terminal-speed equations.
Independent educational reconstruction; not affiliated with or endorsed by the University of Chicago, the American Physical Society, or any historical institution.