1. Forces on the drop
At terminal speed, viscous drag balances the net force. With radius a, oil density ρₒ, air density ρₐ and air viscosity η:
vf = [2a²(ρₒ − ρₐ)g / 9η] C
The electric field is E = V/d. For a negatively charged drop rising against gravity, the magnitude of its charge is:
q = 6πηa(vf + vr) / (CE)
2. Small-drop slip correction
Millikan noted that plain Stokes drag fails as a drop approaches the gas mean-free-path scale. This reconstruction uses a first-order Cunningham-style factor C = 1 + ℓ/a, with ℓ = 81.8 nm at the reference pressure, derived from Millikan’s historical fitted slip coefficient. The radius is recovered from the quadratic settling-speed equation. Constants include ρₒ = 919.9 kg/m³ (historical), ρₐ ≈ 1.193 kg/m³ at 23 °C (modern reference), g = 9.80665 m/s² and the exact SI Boltzmann constant.
3. Real measurement noise
Thermal molecular impacts produce Brownian diffusion. The Einstein relation gives D = kBT/ζ, where ζ = 6πηa/C. The first-passage time over distance L follows the inverse-Gaussian distribution for drifted Brownian motion, with mean L/v and shape L²/(2D). The animated path is integrated with fixed-step Euler–Maruyama increments Δx = vΔt + √(2DΔt)Z, then time-aligned to that sampled crossing. Each reading also receives independent Gaussian chronograph scatter and microscope-position uncertainty. The noise is physical, not arbitrary visual jitter.
4. How the charge step is found
Each measured drop charge is an unknown integer multiple of the elementary charge. A bounded grid search assigns integer levels from one to five (an illustrative search bound) and minimises the weighted residual. A second weighted least-squares calculation checks the fitted step. A parametric Monte Carlo re-fit estimates how strongly the noisy observations constrain that step.
5. What is simplified
The reconstruction assumes spherical drops, laminar terminal flow, a fixed atmospheric pressure and a first-order slip correction. It neglects charge-dependent deformation, evaporation, convection currents, field non-uniformity and detailed optical calibration. The animation is scaled and time-compressed by a factor of 12 for display; the physical trajectory and noise are computed in SI units. The synthetic data are not Millikan’s digitised raw observations.
Independent educational reconstruction; not affiliated with Robert A. Millikan, the University of Chicago, the American Physical Society or NIST.