A charged drop in a quiet chamber
What the observer sees
The charge ladder
Experimental controls
Independent numerical checks
Millikan’s 1913 error bar
The small probable error describes scatter; the wider published error bar includes estimated apparatus uncertainties.
FIELD GUIDEThe science: forces, noise and the charge quantum+
Terminal motion
With the field off, buoyant weight balances viscous drag:
The drag coefficient uses a first-order slip correction:
Charge from rise and fall
When the field is switched on, the electric force pulls the charged drop upward. Combining the two terminal-speed balances gives:
The measured charge states are fitted to \(q_i\approx n_i e\). The slope through the origin is the reconstructed elementary charge.
The real noise model
At the measurement timescale the drop is overdamped. Brownian displacement follows the Langevin limit:
Each trial stops at the first crossing of the microscope tracking distance. The Hipp chronoscope then rounds the time to its selected readout increment. The error estimate propagates both first-passage Brownian timing variance and chronoscope quantisation.
What is simplified
- The drop is a rigid sphere; the field and air properties are uniform.
- Stokes drag with Millikan’s first-order empirical slip coefficient is used; evaporation, convection and charge leakage are omitted.
- The representative radius is taken from the historical Drop 1 table. The consecutive charge counts are illustrative, not claimed to be that drop’s original sequence.
- This is a transparent reconstruction of the timing method, not a digitisation of all 58 published drops or a reproduction of Millikan’s full graphical slip correction.