Presets
Playback
Parameters
Camera
Layers
Quality
Model check
The science
What you see. One cell of an electrolytic manganese plant: 16 stainless-steel cathodes and 17 lead-silver anodes hang in a tank of ammonium-sulphate catholyte; every cathode sits in a diaphragm bag so the acid made at the anode cannot reach it. Manganese plates on both faces of each cathode as a bright sheet. Small dots are hydrogen leaving the cathodes and oxygen leaving the anodes. The head tank feeds fresh manganese solution, the overflow carries the depleted solution away, and the rectifier supplies the direct current.
Why hydrogen competes. Manganese is far below hydrogen in the electrochemical series (E(Mn²⁺/Mn) = −1.18 V against about −0.43 V for hydrogen at pH 7), so the cathode would produce only hydrogen if hydrogen were easy on a manganese surface. It is not: hydrogen needs a large overpotential there, and manganese deposits at a potential where both reactions run in parallel. Each is a Tafel branch, j = j₀ exp(−αF(E − Eeq)/RT), and manganese is capped by diffusion, jlim = 2FDc/δ. The simulation solves jMn(E) + jH(E) = j for the cathode potential E; the current efficiency is CE = jMn/j. Less manganese in the solution, lower pH, no selenium or a hotter cell all push the balance toward hydrogen, which is why plants control all four.
Cell voltage. U = [E(O₂) − E(Mn)] + ηa + |ηc| + j(gap/κ + Rdia). The reversible part is about 2.4 V (checked against the Gibbs energies of formation); the rest is overpotentials and the ohmic drop in the electrolyte, so the plant runs at roughly twice the thermodynamic minimum. Energy per kilogram is U · 2F / (CE · M), typically a few kWh/kg in plants.
Mass balance and Faraday's law. Manganese is deposited at dm/dt = CE · I · M / (2F). The catholyte volume obeys V dc/dt = Q (cfeed − c) − dm/dt; with too little feed the concentration falls, the diffusion limit falls, and the current efficiency collapses. The deposit thickness is m / (ρ A); the page draws it six times thicker than true by default so it is visible (a toggle shows the true thickness).
Heat and gas. Heat released in the bath is the electrical power minus the enthalpy of the two cathode reactions and the oxygen reaction (2.625 V-equivalent for manganese, 1.481 V for hydrogen), which sets the cooling-water need. Hydrogen is flammable from 4 vol%, so the page shows the extraction-air flow that keeps the duct at a quarter of that.
Honest simplifications. The exchange current densities, transfer coefficients, activity coefficient (0.25), diffusion layer (100 µm), conductivity (14 S/m at 40 °C) and the diaphragm resistance are calibrated illustrative values, chosen so that the default point lands at the typical plant range (CE in the 60s of per cent, 5 to 6 V, a few kWh/kg); they are not measured constants of any plant. Real cells also have sludge, anode corrosion, manganese re-dissolution at high temperature, bubble screening of the electrolyte, pH drift and impurity effects that are not modelled. The page does not model selenium chemistry beyond a simple reduction of the hydrogen exchange current, and it does not claim the trends are exact; they are qualitatively those reported for electrolytic manganese.
Checks. (1) The standard decomposition voltage computed from Gibbs energies of formation equals the difference of the electrode potentials used in the model. (2) At five operating points the partial currents sum to the imposed density, and bisection agrees with a brute-force 60,000-point scan. (3) The catholyte balance integrated numerically matches the closed-form solution for a constant plating rate, and the removed mass equals rate times time. (4) The cathode area is read from the Blender mesh and the Faraday thickness from the cell mass equals the per-area formula.