From falling weight to temperature
The effective paired load loses gravitational potential energy as it descends. For total fall height H = n h:
W = M g n h
The water and metal vessel share the temperature rise. The vessel and brass wheel are represented by their water-equivalent heat capacity:
C = (mw + mv,eq) cw
During Joule’s 35-minute run TEXTBOOK, heat exchange with the room follows a lumped Newton-cooling model:
C dθ/dt = P − Kθ
For constant input power, the closed-form temperature rise is θ = (W/Kt)(1 − e−Kt/C). The app also integrates this equation at a fixed one-second step. The known leak factor is applied as a blank-run correction before estimating the equivalent.
The measured equivalent is Ĵ = Wmeas / [meq,g ΔTcorrected], where grams × degrees Celsius is the numerical heat in small calories. The modern thermochemical calorie is 4.184 J.
Noise model and error bars
- Each thermometer endpoint receives independent Gaussian read noise. The baseline 0.0028 °C is the Celsius equivalent of Joule’s stated discernible 1/200 °F.
- Residual thermal drift is Gaussian with σ = 0.020 °C by default. This is reconstructed from the standard deviation of the 40 raw friction temperature gains in Table I: 0.03595 °F. Joule did not publish formal confidence intervals; the exhibit shows the scatter as a reconstructed one-sigma bar.
- Total fall height varies with a Gaussian 0.320% relative standard deviation, reconstructed from the 40 recorded heights in the same table.
- The noise generator is seeded and uses a Box–Muller normal variate. A run is marked unresolved when its temperature signal is too small relative to its noise; it is never forced into a numerical answer.
Simplifications
The visual wheel and falling weights are scaled. The load control is the effective combined load after Joule’s pulley-friction correction; it is not a direct reproduction of the two separate scale readings. The water-equivalent vessel capacity is fixed at the published value. The room conductance is illustrative because Joule reported empirical radiation corrections rather than a modern heat-transfer coefficient. The model assumes the calibrated leak correction is known exactly and neglects evaporation, temperature-dependent heat capacity, and local temperature gradients.
This educational reconstruction is independent and is not affiliated with the Royal Society or the Science Museum Group.