How an ion can orbit nothing.
A Penning trap confines a charged particle without touching it. The vessel is a precision balance between electric and magnetic forces; the ion's motion is the instrument.
01 / What is being modelled?
For an ion of mass m and charge q, the Lorentz equation is m a = q(E + v × B). A static quadrupole electric potential, φ = V₀( z² − (x²+y²)/2 ) / (2d²), pulls a positive ion back toward the central plane along z, but pushes it outward radially. The axial restoring frequency is ωz = √(qV₀/md²). A uniform solenoidal field B along z supplies the magnetic curvature that prevents radial escape. The free cyclotron frequency is ωc = qB/m. Stable radial motion exists when ωc² > 2ωz². These formulas assume positive ions and V₀ > 0.
02 / The three characteristic oscillations
Confinement contains three identifiable motions: a fast modified cyclotron orbit, a slow magnetron drift, and an independent axial bounce. The radial angular frequencies are ω± = (ωc ± √(ωc² − 2ωz²))/2. Notice the sum rule ω+ + ω− = ωc. The frequency indicators report these analytical values in kilohertz. The moving particle is not an animation of those formulas: a second-order Boris-type particle integrator advances the Lorentz equation in SI metres and seconds.
03 / Operating the chamber
Choose an ion, set B and V₀, then press START. The gold concentric electrodes create the potential; luminous copper solenoid turns represent the externally imposed magnetic field. Drag the view to rotate; Shift+drag or right-drag to pan; scroll or pinch to zoom. Drag the green launch marker directly on the horizontal plane to move the initial ion position. Drag the upper gold handle up or down to adjust the characteristic trap dimension d. A camera-reset button restores the original perspective. Touch controls follow the same principles. The ion trail records computed position samples; field tracers approximate integral curves of the modelled magnetic field, not ion paths.
04 / Station 1 — Confinement
First try BALANCED, then WIDE ORBIT. Observe the radial distance and axial coordinate on the oscilloscope. Increase B while holding V₀ fixed: the modified cyclotron orbit tightens, whereas magnetron drift generally becomes slower. Decreasing ion mass increases q/m and changes every frequency. The energy display is the sum of kinetic energy and quadrupole potential energy in electronvolts; the conservation indicator compares the current energy with the initial value when no RF field acts.
05 / Station 2 — RF spectroscopy
An oscillating electric field is applied in the transverse plane: Erf = E₀(cos ωt, −sin ωt, 0). The drive frequency is expressed as a ratio to the predicted modified cyclotron frequency. Set the amplitude above zero and compare the response near and away from a ratio of one. The second chart performs short real numerical integrations over a sweep of drive frequencies and plots the resulting change in particle kinetic energy, not a sketched Lorentzian. Large pulses can cause electrode losses, and a negative energy change is physically possible because field–particle energy transfer depends on phase.
06 / Station 3 — Stability atlas
The map displays the exact uniform-field discriminant D = ωc² − 2ωz² over a grid of B and V₀. Each pixel follows the mathematical criterion; the white cross marks the current controls. Slide toward the boundary and examine the frequency readouts: as D tends to zero, the two radial branches approach each other. Beyond it, the ideal trap can no longer confine general radial trajectories. Try the EDGE CASE preset and change B in small increments.
07 / Station 4 — Magnetic bottle
A spatially varying field bends the magnetic lines. This lab uses Bx = −B₀βxz/d², By = −B₀βyz/d² and Bz = B₀[1 + β(z² − (x²+y²)/2)/d²]. The polynomial satisfies both ∇·B = 0 and ∇×B = 0 exactly within its model domain. Magnetic gradients couple the otherwise independent motions; the uniform-field normal-mode formulas in the instrument panel become a reference rather than exact bottle frequencies. Try positive and negative β at equal launch conditions. This is a local analytic field approximation, not a complete coil solution.
08 / Station 5 — Injection and capture
The ion injector specifies three velocity components in metres per second. Move the launch marker to test off-axis injection and change vx, vy and vz. A trajectory is classified as lost when it crosses the chosen virtual cylindrical or axial aperture. The aperture is an explicit numerical boundary, not a simulated solid collision or an exact electrode surface. Reset to reproduce your chosen initial conditions. The detector's position is a reference surface, and the simulated ion crossing it is indicated by a live event counter.
09 / Measurements and scientific practice
Capture readings to the field notebook; the data can be exported as a CSV file for plotting or uncertainty calculations. Recorded rows include the species, field, voltage, geometry, simulated time, radial position, energy, and frequencies. Compare runs by changing one control at a time. Hypothesis: doubling B at constant q/m approximately doubles free cyclotron frequency. Hypothesis: increasing V₀ raises the axial frequency as √V₀. Hypothesis: increasing mass reduces the cyclotron frequency in inverse proportion to mass. Test each claim quantitatively rather than by eye.
10 / Limits and vocabulary
This is a single-ion, nonrelativistic, classical model. It omits collisions, space charge, image-charge effects, field noise, RF electronics, radiative damping, finite electrodes, and vacuum breakdown. The rendered apparatus is an explanatory design, not an engineering blueprint. Cyclotron motion is magnetic gyration; magnetron motion is slow radial guiding-centre circulation; quadrupole means a potential quadratic in position; resonance is enhanced coherent energy exchange under periodic forcing; adiabatic invariant is a quantity approximately preserved under sufficiently slow field changes. Further questions: how would damping change the spectrum? Which ion species give separable spectral peaks? Why must a purely static electrostatic field fail to trap in all three dimensions?