01 / INTRODUCTIONWhy a free ion does not escape
A positive ion in a uniform magnetic field feels the Lorentz force q(v × B). This bends its motion sideways but cannot remove energy: the force is always perpendicular to velocity. A magnetic field alone cannot confine the particle along the field line. A Penning trap adds a static electric quadrupole made by a central ring electrode and two endcap electrodes. The endcaps restore an ion displaced axially, while the same electrostatic potential pushes it radially outward. Magnetic curvature prevents that radial instability when the field is sufficiently strong.
The apparatus is an idealised single-ion experiment. Its large visible trajectory is a highly magnified depiction of millimetre-scale motion. The physical field formulas, rather than the decorative electrode meshes, determine every trajectory and reading.
02 / MATHEMATICAL MODELOne equation, three distinct frequencies
For a positive ion of mass m and charge q = e, choose magnetic field B along the vertical z-axis and an electrostatic potential Φ = U(2z² − x² − y²)/(4d²). The characteristic length d is 12.0 mm. The electric field is E = −∇Φ, and Newton's equation becomes m d²r/dt² = q(E + v × B). The axial angular frequency is ωz = √(qU/md²); the bare cyclotron frequency is ωc = qB/m.
The coupled radial solution splits into ω± = (ωc ± √(ωc² − 2ωz²))/2. Plus is the rapid modified cyclotron circle; minus is the slower magnetron drift. Physical frequencies in hertz equal angular frequencies divided by 2π. In the perfect quadratic trap, ω+ + ω− = ωc, which is a useful laboratory check.
03 / ORBIT CHAMBERLaunch, watch, measure
Choose Calcium precision, drag the rose injector to change the initial radial position, and pull the amber velocity handle to change the starting velocity. The glowing path follows the exact analytical solution for the stable ideal trap, updated from elapsed simulation time instead of frame count. Change the magnetic field while leaving voltage fixed: hypothesise whether the fast orbit tightens or widens. Pause to take a measurement, then compare a longer run in the oscilloscope. The turquoise probe can be moved around the centre to measure the ideal quadrupole field magnitude and potential. Use the field notebook to collect controlled comparisons; it never inserts invented experimental noise.
04 / MODE SEPARATORResolve the hidden radial dance
The radial position is the sum of two clockwise complex circular motions, conventionally called the fast modified cyclotron mode and the slow magnetron mode for a positive ion with B pointing upward. The Mode Separator displays their analytical components as additional markers and compares three calculated frequency peaks. Vary the injection speed to alter their amplitudes without changing their natural frequencies. Challenge yourself to identify the difference between an initial-condition change and a change in the trap's physical eigenfrequencies. Axial oscillation is independent of radial phase in this ideal model, so a change in the launch height modifies axial amplitude but not its frequency.
05 / STABILITY ATLASFind the edge of confinement
A stable ideal Penning trap requires ωc² greater than 2ωz². Thus the critical endcap voltage is Ucrit = qB²d²/(2m). Switch to Stability Atlas: its main chart shows this calculated voltage boundary for a range of magnetic fields. Click the plot to choose a new B and U pair, and watch the field arrows change with the electrical settings. The coloured point is a calculated operating condition, not a noisy observation. Beyond the boundary, the characteristic radial modes lose their stable oscillatory interpretation; the display clearly labels that regime instead of pretending a bounded orbit still exists.
06 / MASS FINGERPRINTIdentify an ion by its music
Magnetic confinement is sensitive to charge-to-mass ratio. In Mass Fingerprint, scan the mass of a singly charged ion while keeping B and U fixed. The graph plots its calculated modified cyclotron frequency: heavier ions tend to orbit more slowly, and the stability boundary can exclude sufficiently heavy ions. Click on the curve to choose a mass or switch presets to compare selected ionic masses. Penning-trap frequency measurements are used for precision mass spectrometry, nuclear mass determinations, and atomic measurements. This ideal lab omits real detector electronics, molecular charge mixtures, and nonuniform magnetic fields.
07 / DRIVEN RESONANCEExcite the ion without touching it
In RF Resonance, a circularly polarised electric field ERF(t) = E₀[cos(2πfRFt), −sin(2πfRFt), 0] acts on the ion. The full Lorentz equation is integrated with a fixed-step fourth-order Runge–Kutta method. The frequency sweep performs a fresh numerical experiment at each point: an initially axially displaced ion receives the same drive for 105 microseconds, then its maximal radial displacement over the last quarter of the window is measured. Look for resonance near the fast cyclotron frequency and a possible second peak near the slow magnetron frequency. Increase E₀: the response becomes stronger, but in the ideal, undamped model the peak is finite only because excitation time is finite. The scan is not a fabricated Lorentzian or a measured spectrum.
08 / ACCURACY & LIMITATIONSWhat the museum model deliberately leaves out
The closed-form orbit solver is exact for a single classical positive ion in an infinite quadratic electrostatic potential and a spatially uniform static B field. The rotating electric drive is an added ideal field, not a reconstructed electrode circuit. No collisions, gas damping, radiation loss, relativistic correction, image charges, magnet imperfections, quantum energy levels, or Coulomb interactions between multiple ions are modelled. Electrode surfaces are illustrative; the field is not solved from that finite geometry. The conserved quantity for unforced trajectories is ½m|v|² + qΦ, not kinetic energy by itself. The real numerical integration uses sufficiently small fixed steps for the fast frequency. Instability in a finite real apparatus would lead to loss, but this virtual laboratory flags the analytic stability limit rather than simulating electrode impacts.
09 / GLOSSARY & INQUIRYQuestions for a new investigation
Quadrupole: a potential quadratic in position, harmonic near the centre. Magnetron motion: the slow radial drift component in a Penning trap. Eigenfrequency: a natural oscillation frequency fixed by system parameters. Resonance: enhanced motion when a forcing frequency matches a natural mode. Atomic mass unit: approximately 1.66054 × 10⁻²⁷ kg. Probe: a noninvasive readout of the ideal potential and electric field at a selected position.
Further questions: How does doubling B affect the critical voltage? Does changing the injection velocity shift the spectral peaks? What would a weak viscous drag term do to the driven-resonance shape? How would an ion with two elementary positive charges differ from the singly charged ions in this laboratory?