Solar Panel I-V Curve and Maximum Power Point

Single-diode model of a 60-cell module. Change light, angle, heat and load.

Presets

Controls

Live readouts

Independent checks

Experiment

Run the experiment to measure the temperature coefficient of voltage.
The science

A solar cell is a large-area p-n junction. Light creates a photocurrent Iph; the junction itself behaves like a diode that leaks current back. The standard single-diode model for a 60-cell module is

I = Iph - I0 [exp((V + I Rs) / (n Ns kT/q)) - 1] - (V + I Rs) / Rsh

  • Iph = Isc,ref (G/1000) cos(theta) [1 + 0.0005 (T - 25)]: current follows the light that actually hits the surface (Lambert cosine law) with a small temperature gain.
  • I0 (diode saturation current) grows as T^3 exp(-Eg/(n k T)), Eg = 1.12 eV for silicon. This is why Voc falls by about 0.33 %/K and hot panels lose power.
  • Rs (wiring and contact resistance) bends the knee of the curve; Rsh = 300 ohm is a fixed leak.
  • Fill factor FF = Pmax / (Isc Voc); efficiency uses a 1.65 m2 module area.
  • A load resistor fixes the operating point where I = V/R meets the curve. Only one resistance extracts the maximum; an MPPT tracker keeps the module at that point.

Honest simplifications: Isc 9 A, Voc 37 V at 25 C and n = 1.3 are typical illustrative datasheet values, not a specific product. Reflection grows faster than cosine at grazing angles and is ignored. Spectrum, shading and cell mismatch are not modelled. Cell temperature is a slider; no thermal model of the roof.

Checks shown in the page: open-circuit voltage against a ln(Iph/I0+1); the numerical I(V) against an independent Lambert-W closed form (Rsh to infinity); Pmax by golden-section versus a 4000-point scan; and the temperature coefficient of Voc against the analytic derivative.