Shear-building model
Each floor is a lumped mass m connected to the one below by a storey spring k (the stiffness of the columns). With relative displacements u measured from the moving ground, the equations of motion are M u'' + C u' + K u = -M 1 ag(t). K is tridiagonal, so each time step is a cheap tridiagonal solve. Time integration is the Newmark average-acceleration method (beta 1/4, gamma 1/2), which is unconditionally stable and conserves energy for an undamped frame.
Natural frequencies
For N equal floors fixed at the base the frequencies are ωq = 2 sqrt(k/m) sin((2q-1)π / (2(2N+1))) with mode shapes φq(i) = sin(i(2q-1)π/(2N+1)). A taller frame (larger N) or softer storeys (smaller k) lowers f1; the first period of a real tall building is roughly 0.1 s per floor. Damping is Rayleigh type, C = αM + βK, fitted so that modes 1 and 3 have the chosen damping ratio.
Resonance
Harmonic ground motion at ω drives a mode with the dynamic amplification 1 / sqrt((1-r²)² + (2ζr)²), r = ω/ωq. At r = 1 the response is 1/(2ζ) times the static one, which is why a 0.1 g shake at f1 can do more harm than a 0.5 g shake at a far-off frequency. The frequency-response graph is computed by solving (K - ω²M + iωC) x = -M 1 directly.
Tuned mass damper
A damper mass μN m on the roof with spring and dashpot tuned by Den Hartog's rules, ft = f1/(1+μ) and ζt = sqrt(3μ/(8(1+μ)³)), splits the single resonance peak into two lower peaks and removes much of the response (switch on the preset "Resonance + tuned mass damper" and compare the roof displacement graph).
Soft storey
If one storey is much weaker than the rest, the drift concentrates there: the drift ratio plot shows a spike at that storey even though the roof moves less.
Model checks (run in the page)
1. Free vibration of a 10-storey uniform frame must reproduce the closed-form period above. 2. The steady-state roof amplitude at resonance from the time-domain integration must equal the frequency-domain complex solve (two independent methods). 3. Energy balance: input work equals kinetic + strain + dissipated energy.
Honest simplifications
The frame is linear elastic: it never yields, cracks or collapses, so "damage" is an indicator (peak drift ratio versus your chosen limit), not a prediction. Floors are rigid, motion is horizontal in one direction, there is no soil-structure interaction, torsion or P-delta effect. Ground motions are synthetic records scaled to the chosen peak ground acceleration. Real design uses recorded motions, nonlinear analysis and local building codes; this is a teaching model of inanimate structures only.
3D view
Everything you see is drawn from the same numbers as the 2D page. The ground block, houses, trees and cars move with the ground; the building is a stack of instanced storeys, each sheared between the displacement of the floor below and the floor above. Displacements are multiplied by the drawing amplification slider (real displacements are centimetres); the fixed grid wall and the scale bar are the stationary reference. Double-click the scene to give the frame a push.